I
Ian ValenciaAug 18, 2025
What to do if CashCode FrontLoad MFLV-2110 cassette is full?
- FFrederick MillerAug 19, 2025
If the cassette is full, remove it, empty it, and then re-insert it into the CashCode Bank Note Validator.
What to do if CashCode FrontLoad MFLV-2110 cassette is full?
If the cassette is full, remove it, empty it, and then re-insert it into the CashCode Bank Note Validator.
What to do if there is mechanical jam in CashCode FrontLoad MFLV-2110 cassette or stacker motor failure?
If you experience a mechanical jam in the cassette or stacker motor failure, remove the cassette from the bill validator and extract any jammed bills. Then, turn the power on and check if the stacker motor rotates.
What to do if the CashCode FrontLoad MFLV-2110 Bank Note Validator cassette is removed?
If the cassette is removed from the bill validator, check if it is installed correctly.
What to do if CashCode Bank Note Validator has failure of optical sensors?
If there is a failure of the optical sensors, open the validator head guide and clean the optical sensors. Remove the Sense-A-Click module, check the connectors, and then change the Sense-A-Click module. See the maintenance section for cleaning details on these sensors.
What to do if CashCode FrontLoad MFLV-2110 Bank Note Validator shows overload of transport motor?
If there is an overload of the transport motor, open the validator head guide and check to see if the path is clean.
What to do if CashCode Bank Note Validator shows failure of inductive sensors?
If there is a failure of the inductive sensors, open the validator head guide and clean the inductive sensors. Remove the lower Sense-A-Click module with inductive sensors and check the connectors. Change the lower Sense-A-Click module. See the maintenance section for cleaning of these sensors.
What to do if CashCode FrontLoad MFLV-2110 Bank Note Validator has failure of dielectric sensors?
If there is a failure of the dielectric sensors, check if the Sense-A-Click module corresponds to the correct software type/version and replace the Sense-A-Click module.
What to do if the CashCode FrontLoad MFLV-2110 Bank Note Validator alignment mechanism fails?
If the alignment mechanism fails, open the validator head guide and check to see if the path is clean. Close the guide and turn off the power. After five seconds, turn the power on; the alignment mechanism will self-adjust.
What to do if CashCode FrontLoad MFLV-2110 transporting motor fails?
If the transporting motor fails, open the validator head guide and clean the path. Close the validator head guide. If the validator does not start, turn off the power, clean the receiving path, insert the validator head, and turn the power on.
Why is the speed of CashCode FrontLoad MFLV-2110 Bank Note Validator transporting motor too fast?
The speed of the transporting motor might be too fast because of the power supply voltage. Check the power supply voltage.
Details the 8-position DIP switches (SW1) for bill denomination settings.
Defines the 4-position DIP switches (SW2) for bill orientation and communication.
Instructions for collecting validated bills by removing the cassette.
Step-by-step guide for updating software using a single-download memory card.
Procedure for updating software using a multi-download smart stick.
Lists status light indications, errors, and fault handling for software updates.
Details diagnostic errors indicated by the status light during operation mode.
| Brand | CashCode |
|---|---|
| Model | FrontLoad MFLV-2110 |
| Category | Bank Note Validator |
| Language | English |