What to do if CashCode FrontLoad Bank Note Validator cassette is full?
- SShawn CarpenterAug 19, 2025
If the cassette is full, remove it, empty it, and then re-insert it into the CashCode Bank Note Validator.
What to do if CashCode FrontLoad Bank Note Validator cassette is full?
If the cassette is full, remove it, empty it, and then re-insert it into the CashCode Bank Note Validator.
What to do if there is mechanical jam in CashCode FrontLoad cassette or stacker motor failure?
If you experience a mechanical jam in the cassette or stacker motor failure, remove the cassette from the bill validator and extract any jammed bills. Then, turn the power on and check if the stacker motor rotates.
What to do if the CashCode Bank Note Validator cassette is removed?
If the cassette is removed from the bill validator, check if it is installed correctly.
What to do if CashCode FrontLoad Bank Note Validator has failure of optical sensors?
If there is a failure of the optical sensors, open the validator head guide and clean the optical sensors. Remove the Sense-A-Click module, check the connectors, and then change the Sense-A-Click module. See the maintenance section for cleaning details on these sensors.
What to do if CashCode Bank Note Validator shows overload of transport motor?
If there is an overload of the transport motor, open the validator head guide and check to see if the path is clean.
What to do if CashCode Bank Note Validator shows failure of inductive sensors?
If there is a failure of the inductive sensors, open the validator head guide and clean the inductive sensors. Remove the lower Sense-A-Click module with inductive sensors and check the connectors. Change the lower Sense-A-Click module. See the maintenance section for cleaning of these sensors.
What to do if CashCode FrontLoad has failure of dielectric sensors?
If there is a failure of the dielectric sensors, check if the Sense-A-Click module corresponds to the correct software type/version and replace the Sense-A-Click module.
What to do if the CashCode Bank Note Validator alignment mechanism fails?
If the alignment mechanism fails, open the validator head guide and check to see if the path is clean. Close the guide and turn off the power. After five seconds, turn the power on; the alignment mechanism will self-adjust.
What to do if CashCode FrontLoad Bank Note Validator transporting motor fails?
If the transporting motor fails, open the validator head guide and clean the path. Close the validator head guide. If the validator does not start, turn off the power, clean the receiving path, insert the validator head, and turn the power on.
Why is the speed of CashCode FrontLoad Bank Note Validator transporting motor too fast?
The speed of the transporting motor might be too fast because of the power supply voltage. Check the power supply voltage.
Describes the Validating Head options: fixed-width path and centering mechanism.
Standard Bezel with status indication light.
Bezel with running lights and status light combined.
Bezel with runway lights and a digital display.
Bezel with runway lights and an IR communication port.
Bezel with runway lights, digital display, and IR communication port.
Bezel with Smart Card reader supporting up to 4 payment systems.
Bezel designed for 'Double Diamond' Gaming machine.
GPT compatible Bezel featuring runway lights.
Bezel designed to be coin-proof.
Reversed metal coin-proof Bezel for specific cassette installation.
Open metal Bezel design.
Cole compatible Bezel, Variant A.
Cole compatible Bezel, Variant B.
Cole compatible Bezel, Variant C.
Cole compatible Bezel, Variant D.
Step-by-step guide for installing the lock mechanism on the 600-bill validator base.
Step-by-step guide for installing the lock mechanism on the 1000-bill validator base.
Procedure for installing security locks into the Cassette using provided parts.
Defines the 8-position DIP switches (SW1) for bill denomination settings.
Defines the 4-position DIP switches (SW2) for orientation, communication speed, and mode.
Instructions for updating software using a multi-download Memory Card.
Procedure for downloading software via the interface connector using a CashCode Adaptor.
Details errors indicated by status light flashes in operation mode, starting with 1. RED.
Error description for 2 RED flashes: CPU exchange with Sense-a-Click modules.
Error description for 3 RED flashes: Cassette is full.
Error description for 4 RED flashes: Mechanical jam or stacker motor failure.
Error description for 5 RED flashes: Failure of dielectric sensors.
Error description for 6 RED flashes: Failure of optical sensors.
Error description for 7 RED flashes: Failure of inductive sensors.
Error description for 8 RED flashes: Failure of transporting motor.
Error description for 9 RED flashes: Speed of transporting motor is too fast.
Error description for 10 RED flashes: Failure in alignment mechanism.
Error description for 11 RED flashes: Bill pathway is not empty.
Error description for 12 RED flashes: Bill jam in entry slot of cassette.
Error description for 13 RED flashes: Overload of transport motor.
| Operating Voltage | 12V DC |
|---|---|
| Communication Interface | USB |
| Operating Temperature | 0°C to 45°C |
| Humidity | 5% to 95% (non-condensing) |
| Protocols | CCNet, MDB |
| Storage Temperature | -20°C to +70°C |