What to do if CashCode FrontLoad bill pathway is not empty?
- SSarah PettySep 12, 2025
If the bill pathway is not empty, open the receiving path and check that it is clean.
What to do if CashCode FrontLoad bill pathway is not empty?
If the bill pathway is not empty, open the receiving path and check that it is clean.
What to do if CashCode FrontLoad has an error during CPU exchange with Sense-A-Click modules?
If an error occurred during CPU exchange with Sense-A-Click modules, disconnect power from the validator. Open the cover, check if Sense-A-Click modules are properly installed, and verify that Sense-A-Click modules correspond to the correct software type/version.
What to do if there is a bill jam in entry slot of CashCode Bank Note Validator cassette and no credit issued?
If there is a bill jam in the entry slot of the cassette and no credit is issued, remove the cassette from the bill validator and clean the path.
Describes the Validating Head options: fixed-width path and centering mechanism.
Standard Bezel with status indication light.
Bezel with running lights and status light combined.
Bezel with runway lights and a digital display.
Bezel with runway lights and an IR communication port.
Bezel with runway lights, digital display, and IR communication port.
Bezel with Smart Card reader supporting up to 4 payment systems.
Bezel designed for 'Double Diamond' Gaming machine.
GPT compatible Bezel featuring runway lights.
Bezel designed to be coin-proof.
Reversed metal coin-proof Bezel for specific cassette installation.
Open metal Bezel design.
Cole compatible Bezel, Variant A.
Cole compatible Bezel, Variant B.
Cole compatible Bezel, Variant C.
Cole compatible Bezel, Variant D.
Step-by-step guide for installing the lock mechanism on the 600-bill validator base.
Step-by-step guide for installing the lock mechanism on the 1000-bill validator base.
Procedure for installing security locks into the Cassette using provided parts.
Defines the 8-position DIP switches (SW1) for bill denomination settings.
Defines the 4-position DIP switches (SW2) for orientation, communication speed, and mode.
Instructions for updating software using a multi-download Memory Card.
Procedure for downloading software via the interface connector using a CashCode Adaptor.
Details errors indicated by status light flashes in operation mode, starting with 1. RED.
Error description for 2 RED flashes: CPU exchange with Sense-a-Click modules.
Error description for 3 RED flashes: Cassette is full.
Error description for 4 RED flashes: Mechanical jam or stacker motor failure.
Error description for 5 RED flashes: Failure of dielectric sensors.
Error description for 6 RED flashes: Failure of optical sensors.
Error description for 7 RED flashes: Failure of inductive sensors.
Error description for 8 RED flashes: Failure of transporting motor.
Error description for 9 RED flashes: Speed of transporting motor is too fast.
Error description for 10 RED flashes: Failure in alignment mechanism.
Error description for 11 RED flashes: Bill pathway is not empty.
Error description for 12 RED flashes: Bill jam in entry slot of cassette.
Error description for 13 RED flashes: Overload of transport motor.
| Operating Voltage | 12V DC |
|---|---|
| Communication Interface | USB |
| Operating Temperature | 0°C to 45°C |
| Humidity | 5% to 95% (non-condensing) |
| Protocols | CCNet, MDB |
| Storage Temperature | -20°C to +70°C |