E-133
Error Message Cause Action
Math ERROR An intermediate or the fi nal result
of the calculation falls outside of
the allowable calculation range.
An input value is outside the
allowable input range.
You are trying to perform an illegal
mathematical operation (such as
division by zero).
You input a complex number as an
argument of a function.
Check your input values and
reduce the number of digits, if
required.
When using independent memory
or a variable as the argument
of a function, make sure that
the memory or variable value is
within the allowable range for the
function.
Complex numbers cannot be used
as arguments of trigonometric
functions and other functions.
Change the argument to a real
number.
Stack ERROR The calculation has causes the
capacity of the numeric stack
or the command stack to be
exceeded.
The calculation includes more
than 10 matrices.
Simplify the calculation expression
so it does not exceed the capacity
of the stacks.
Try splitting the calculation into
two or more parts.
Syntax ERROR The syntax of the calculation
expression is wrong.
Check the syntax and make the
required corrections.
Argument ERROR The calculation is using the wrong
argument.
Check how arguments are being
used and make the required
corrections.
Dimension ERROR The matrix used in a calculation
does not contain anything.
You are trying to perform an
addition or other operation
with two matrices of different
dimensions, or some other illegal
matrix operation.
Change the matrix to one that
contains data.
Check the matrices and make
sure they are within the limits
for the type of calculation being
performed.
Can’t Solve SOLVE (page 92) could not obtain
a solution. (Example: X = X + 1)
Check the equation to make sure it
does not contain any errors.
Input an initial value that is close to
the solution and try again.
Time Out Integration or differential calculation
executed, but the solution does not
satisfy end conditions.
• Increase the
tol
value to loosen the
solution conditions and try again.
Solution precision will be lower in
this case.
In the case of differentiation of a
trigonometric function, select Rad
for the angle unit.

Table of Contents