4.2 Electrical Durability
4.2.1 IT-10
Table 4.6
Item Specification Remark
5V, 2.7A Applicable to IT-10M20.
Power consumption
5V, 3.0A Applicable to IT-10M20BR.
Anti-static strength
Malfunction
±4 KV (contact), ±8 KV (in air)
Destruction
±12 KV
Compatible with EN6100-4-2
4.2.2 HA-C60IO/HA-C61IO
Table 4.7
Item Specification Remark
Consumption
current
Approx. 1.0 A/DC12V - While supplying power to the terminal, or
transmitting data to the terminal.
- Applicable to HA-C61IO.
DC5V±5%
Applicable to HA-C60IO.
Input voltage
DC12V
±5%
Applicable to HA-C61IO.
Anti-static strength
Malfunction
±6 KV
Destruction
±12 KV
150 pF, 330 ohm
Line noise strength
(Malfunction)
1,000 V Pulse width: 5 KHz
Burst cycle: 300 msec.
No. of pulses: 75 pcs
Burst period: 15 msec.
Power interruption 10 milliseconds or less
4.2.3 HA-C32DCHG
Table 4.8
Item Specification Remark
Approx. 0.03A When the battery pack is not mounted.
Consumption current
Approx. 0.8A When the battery pack is charged on the
HA-C32DCHG..
Input 12V±5%
Anti-static strength
Malfunction ±8 KV
Destruction ±12 KV
150 pf, 330 ohm
Line noise strength
Malfunction 1,000 V Pulse width: 5 KHz
Burst cycle: 300 msec.
No. of pulses: 75 pcs
Burst period: 15 msec.