7.2 MACHINES WITH WATERCOOLED CONDENSER
By watercooled machines, it is necessary to drain all water from the condensing unit on season
end, so as to avoid drawback when storing in rooms where temperature can sink below 0°C.
After closing water inlet, pull off the outlet pipe from its seat and drain water from the circuit,
completely.
7.3 MACHINES WITH AIRCOOLED CONDENSER
Clean the condenser, periodically, so as to remove dust, paper and what can prevent air from
circulating.
For cleaning, use a brush with long bristles or a bolt of compressed air.
CAUTION
When using compressed air, put on personal protections in order to avoid accidents;
put on protective glasses!
WARNING
Never use sharp metal objects to carry out this operation. Good working of a freezing
plant mostly depends on clean out of the condenser.