2 HP, 8 GALLON, 115 PSI
PORTABLE AIR COMPRESSOR
Model
95386
SET UP AND OPERATING INSTRUCTIONS
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Copyright
©
2006 by Harbor Freight Tools
®
. All rights reserved. No portion of this manual or any artwork
contained herein may be reproduced in any shape or form without the express written consent of
Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein. Tools required for
assembly and service may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
Manual Revised 09k

Other manuals for Central Pneumatic 95386

Questions and Answers:

Central Pneumatic 95386 Specifications

General IconGeneral
BrandCentral Pneumatic
Model95386
CategoryAir Compressor
LanguageEnglish

Summary

Setup and Operating Instructions

Save This Manual

Important Safety Information

General Compressor Safety Warnings

Read all warnings and instructions to avoid electric shock, fire, and serious injury.

Work Area and Electrical Safety

Keep area clean, well-lit, and ensure proper electrical connections.

Personal Safety and Use

Stay alert, use common sense, wear PPE, and use compressor as intended.

Air Compressor Safety Warnings

Risk of Fire or Explosion

Avoid flammable liquids, hot surfaces, and sparks in confined or explosive areas.

Risk of Bursting

Do not adjust regulator higher than attachment's maximum pressure.

Risk of Injury

Do not direct air stream at people or animals.

Extension Cord Safety

Use of extension cords not recommended; follow guidelines if used.

Grounding

Prevent Electric Shock and Death

Ensure proper grounding wire connection to prevent shock and death.

110-120V Grounded Compressors

Details for grounding compressors with three-prong plugs.

Symbology

Electrical Safety Symbols

Symbols for Double Insulated, AC Voltage, and Amperes.

Certification Marks

Marks from CSA and Underwriters Laboratories (UL).

Operational Symbols

Symbols for No Load RPM.

Specifications

Specifications Overview

Details on electrical, air, tank, and oil requirements.

Unpacking and Setup Instructions

Unpacking and Initial Checks

Inspect for damage, check parts, and remove protective plastic.

Pre-Use Safety Review

Read the entire important safety information section before setup or use.

Functions

Component Overview

Diagram showing main parts and their functions.

Compressor Setup and Assembly

Area Set Up

Designate work area, locate compressor on level surface with space.

Attaching Foot and Wheels

Instructions for attaching the foot and wheels to the air tank.

Installing the Air Filter

Air Filter Installation

Thread the air filter clockwise onto the cylinder head.

Setup and Oil Check

Air Line Setup and Oil Level

Connect air hose, check oil level, and add oil if necessary.

Change Oil After First Hour

First Hour Oil Change

Change compressor oil after the first hour of use to remove debris.

Initial Run of the Air Compressor

Break-in Procedure

Follow steps for initial run: check oil, plug in, run for 30 minutes, then turn off.

General Operating Instructions

Pre-Operation Checks and Connections

Perform checks, close valves, and connect air tool before starting.

Operation and Pressure Adjustment

Power on, build pressure, adjust regulator, and use the air tool.

Post-Operation Shutdown and Bleeding

Turn off, unplug, close valve, bleed tool, and disconnect.

Emergency Depressurization

Quick Depressurization

Turn off compressor, pull safety valve ring to release pressure.

Automatic Shut-off System

Troubleshooting Automatic Shut-off

If compressor shuts off, disconnect tools, wait, press reset button.

Causes of Repeated Shut-off

Check for extension cord issues or air leaks causing frequent cycling.

Maintenance and Servicing

General Maintenance Guidelines

Inspect before use, wipe after use, and handle damaged cords properly.

Maintenance Schedule

Daily, weekly, and monthly checks for optimal performance.

Changing the Oil

Oil Change Procedure

Check oil, drain old oil, and refill with new oil as per instructions.

Draining Moisture from the Tank

Tank Moisture Draining

Release trapped air and moisture from the tank to prevent corrosion.

Air Filter Maintenance

Air Filter Replacement

Check filter weekly and replace as needed, especially in dirty environments.

Troubleshooting

Compressor Start/Stop Issues

Diagnose problems with starting, restarting, or excessive cycling.

Pressure Building Issues

Address slow pressure build or failure to build enough pressure.

Oil Consumption, Noise, and Overheating

Troubleshoot oil consumption, noise, overheating, and air quality.

Air Leaks and Safety Valve

Address air leaks from fittings, tank, and safety valve popping.

Tank Integrity

Check for defective or rusted tanks that may leak air.

Parts List

Part Descriptions and Quantities

List of all parts with their respective quantities.

Assembly Diagram

Component Illustration

Visual guide showing the assembly of all compressor parts.

Limited 1 Year / 90 Day Warranty

Warranty Coverage

Details warranty for tank and other parts, excluding misuse and lack of maintenance.

Warranty Claim Procedure

Steps to return product for warranty service, including proof of purchase.

Legal Rights

Information on specific legal rights and state variations.