1818
E
Electrical Connections
N.B.
Two controllers are available. Select the correct controller drawing from those shown below:
CP77 CONTROLLER -
DOUBLE/SINGLE SWING CONTROLLER WITH MULTIPLE FEATURES
PEDESTRIAN INPUT
NORMAL TRIGGER
PILLAR LIGHT OVER-RIDE
REMOTE STATUS LED
INFRA-RED BEAM
MASTER LIMIT SW OPEN
MASTER LIMIT SW CLOSED
SLAVE LIMIT SW OPEN
SLAVE LIMIT SW CLOSED
+ 12V DC, 3A AUX SUPPLY
SOLENOID STRIKE
15V AC SUPPLY
15V AC SUPPLY
AUTO CLOSE CONTROL
FREE EXIT LOOP
HOLIDAY LOCKOUT
SLAVE MOTOR
BATTERY
MASTER MOTOR
SIGNAL COMMONS (NEG)
PILLAR LIGHT CONTACT
(Potential Free)
1
2
3
4
5
6
7
8
9
10
11 12
13
14
15
16
+
-
}}
}}
}}
}}
}}
A
7 953
1
4
6 8
1210
14
16
11 13 15
2
C
C
D
E
F
G
I
B
H
CP77 CONTROL CARD
CP87 CONTROLLER -
PEDESTRIAN
COMMON (NEG)
LIMIT SWITCH (OPEN)
LIMIT SWITCH (CLOSE)
+ 12V 1A AUX SUPPLY
15V AC INPUT
15V AC INPUT
COMMON (NEG)
TRIGGER
MOTOR
BATTERY
1
2
3
4
5
6
7
8
9
}
}
7 953
4
6 8
CP87 CONTROL CARD
SINGLE MOTOR CONTROLLER WITH BASIC FEATURES
+
--
A B
C
D
1
2