Commissioning cont'd .....
SETUP LINE
TIGHTEN
USING
ALLEN KEY
3030
--
--
--
FIXED PIN
ADJUSTABLE
L/S STRIKER
MOTOR
SHOWN
CLOSING
GATE "CLOSED"
MICROSWITCH
SHOWN ACTIVATED
GATE "OPEN"
MICROSWITCH
NOTE: LHS MOTOR SHOWN
LIMIT SWITCH ADJUSTMENT
DISCONNECT COMMON, IF NECESSARY
TO SET UP (SEE DESCRIPTION ABOVE)
ARRANGE FOR FIXED PIN TO STOP MOTOR IN THE GATE "CLOSED" POSITION (SEE FIG 1 BELOW).
IF ADJUSTABLE L/S STRIKER ARM CAUSES GATE TO STOP, THEN DISCONNECT L/S COMMON
(SEE FIG 2 BELOW) AND ALLOW MOTOR TO DRIVE PAST LIMIT SWITCH SPRING.
WHEN L/S STRIKER ARM IS CLEAR, RECONNECT WIRE.
L/
S OPE
N
L/S
CLOS
E
D
/
S
M
O
N
L
CO
M
}
}
}
TO MICRO-
SWITCHES
TO
MOTOR
TO
EARTH
--
--
--
WITH LIMIT SWITCHES SET FOR THE CORRECT "GATE CLOSED" POSITION, REFIT DRIVE ARM AND
CONNECTING ARM ENSURING THAT THEY ARE IN A COMPLETELY STRAIGHT LINE.
TIGHTEN DRIVE ARM SECURELY USING ALLEN KEY.
DRIVE ARM, BALL JOINT AND CONNECTING ARM MUST LIE DIRECTLY OVER, AND IN LINE WITH, THE
SETUP LINE.
FIG 1