page 24
www.centsys.com
SECTION 6
OPERATOR INSTALLATION
FIGURE 32
FIGURE 33
FIGURE 34. CORRECT AND INCORRECT MOUNTING CONFIGURATIONS FOR THE SDO4
Useaspiritleveltoensurethat
the SDO4 is still level and parallel
to the ceiling. Align the holes of
the punched angle iron mounted
to the ceiling, with the holes on
the punched angle iron mounted
to the drive rail hanger. Secure it
into position using two supplied M8
angeboltsandnutsusinga13mm
socket.
Spirit level
SDO4
SDO4
M8 Flange bolts
M8 Flange
nuts
Punched
angle iron
Punched
angle iron
mounted
to ceiling
RECOMMENDED NOT RECOMMENDED
Usingaspiritlevel,ensure
that the SDO4 is level on
both the X-Axis and Z-Axis
of the horizontal plain.
If it is not, it may cause the
motor to stress, or the drive
rail to twist.