ELECTRICAL SETUP OF ACCESSORIES
6.8. Defaulting the SDO4
Follow the below procedure to default the SDO4 to its factory settings.
1. Remove all power by disconnecting the mains and batteries.
2. Hold Learn (RED) while applying power to the control board.
3. Waituntilthedisplayshows“Fr”,thenreleasethebutton.
Please note that defaulting the SDO4 will clear its setting memory,
therefore any operating parameters will be set to default values and
Limits/Force settings are deleted. Remotes are NOT deleted.