EasyManua.ls Logo

Cerber C816 - Page 25

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
While the system is being within “main programming menu” select section [021] to establish the ding options. The 1 to 6 options will be displayed according to the table below:
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
enabled
*
disabled
Dings upon keyswitch
arming/disarming
KeyswitchDing Enable k1 Disable k1
[2] 2
enabled
*
disabled
Dings upon arming (unless
keyswitch arming)
DingArming minutes k2 hours k2
[3] 3
enabled
*
disabled
Dings upon disarming (unless
keyswitch disarming)
DisarmDing Enable k3 Disable k3
[4] 4
enabled
*
disabled Dings during exit delay
ExitDing Enable k3 Disable k3
[5] 5
enabled
*
disabled
Warning dings during the 3 minutes
before autoarming
AutoarmDing Enable k3 Disable k3
[6] 6
enabled
*
disabled Dings after the exit delay time
AfterExitDing Enable k6 Disable k6
[7] 7
enabled
*
disabled
Warning on keypads’ buzzer when
siren sounds
KpdAlarm Enable k7 Disable k7
[8] 8
*
English Alternate Keypad messages language
KpdsLang English k8 Portug k8
Note: The default programmed options are marked with *.
Press the [1] to [8] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [021] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Notes:
1. One ding means the siren will be activated (will sound) fording time” defined in section [050];
2. More dings means the siren will sound for “ding time” alternating with ding pause” defined in section [050].
Section [022]: Time Measurement Unit for PGM output defined as pulse
While the system is being within “main programming menu” select section [022] to establish the Time Measurement Unit for PGM outputs defined as pulse. The 1 to 6 options will be
displayed according to the table below:
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
minutes
*
seconds PGM1 time measurement unit
TimePGM1 min k1 sec k1
[2] 2
minutes
*
seconds PGM2 time measurement unit
TimePGM2 min k2 sec k2
[3] 3
minutes
*
seconds PGM3 time measurement unit
TimePGM3 min k3 sec k3
[4] 4
minutes
*
seconds PGM4 time measurement unit
TimePGM4 min k4 sec k4
[5] 5
minutes
*
seconds PGM5 time measurement unit
TimePGM5 min k5 sec k5
[6] 6
minutes
*
seconds PGM6 time measurement unit
TimePGM6 min k6 sec k6
Note: The default programmed options are marked with
*
.
Press the [1] to [6] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.