EasyManua.ls Logo

Cerber C816 - Page 26

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [022] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Section [023]: External devices tamper
While the system is being within “main programming menu” select section [023] to establish if tamper of devices connected to the system that have their own box (i.e. keyfob
module) is enabled.
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
enabled
*
disabled Keyfob module tamper
Keyfob tamper Enable k1 Disable k1
[2] 2
enabled
*
disabled PGM expander tamper
PGMExpTamper Enable k2 Disable k2
[3] 3
enabled
*
disabled Zone expander tamper
ZoneExpTamper Enable k3 Disable k3
Note: The default programmed options are marked with *.
Press the [1], [2] or [3] key in order to turn this options enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [023] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Section [024]: Keypads tamper
While the system is being within “main programming menuselect section [024] to establish if own tamper of each keypad is enabled. The 1 to 8 options will be displayed according to
the table below:
Key pressed
to toggle
option
KP-126Pz / KP-164Pz (LED keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
*
enabled disabled Keypad1’ tamper
Kpd1 Tamper Enable k1 Disable k1
[2] 2
*
enabled disabled
Keypad2’ tamper
Kpd2 Tamper Enable k2 Disable k2
[3] 3
*
enabled disabled Keypad3’ tamper
Kpd3 Tamper Enable k3 Disable k3
[4] 4
*
enabled disabled Keypad4’ tamper
Kpd4 Tamper Enable k4 Disable k4
[5] 5
*
enabled disabled Keypad5’ tamper
Kpd5 Tamper Enable k5 Disable k5
[6] 6
*
enabled disabled Keypad6’ tamper
Kpd6 Tamper Enable k6 Disable k6
[7] 7
*
enabled
disabled Keypad7’ tamper
Kpd7 Tamper Enable k7 Disable k7
[8] 8
*
enabled
disabled Keypad8’ tamper
Kpd8 Tamper Enable k8 Disable k8
Note: The default programmed options are marked with *.
Press the [1] to [8] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [024] programming section, waiting for a new
command to enter another section or [#] key to exit the main programming menu.
Section [025]: Keypad zones activation
Each keypad connected to the system has 2 zones that can be activated by the use of programming section [025].
While the system is being within “main programming menu” select section [025] to activate/deactivate keypad zones. The 1 to 8 options will be displayed according to the table below: