2. An additional condition should be met for control panel to automatic initiate the voice/sound reporting on the phone line: at least one of the 4 follow me phone numbers should be
programmed (see programming/selective erasure sessions of the 1 to 4 follow me phone numbers, accessible to the master user by means of one of [*][7][Master Code][5X][Phone
number X][#] or [CODE][Master Code][5X][Phone number X][#] commands) .
3. If second option in this section is set as enabled, then the same condition should be met for “AC power loss” event to automatic initiate the voice/sound reporting on the phone line:
at least one of the 4 follows me phone numbers should be programmed.
4. If third option in this section is set as enabled, then the control panel will answer to the remote interrogation calls (either after “double call” or after the programmed number of rings)
and it will report the system status by specific voice messages or by specific synthesis sounds.
5. If the control panel automatic answers to the remote calls for system status interrogation, then it will report on the phone line the voice message or synthesis sounds specific to the “AC
power loss” event, even if this event hasn’t yet initiated the transmission to the “central station” or the voice/sound dialer hasn’t yet start the voice/sound reporting to the follow me phone
numbers.
6. The control panel can report (upon remote interrogation calls and to the follow me phone numbers, too) up to 8 voice messages only when there it is using the MPV8 voice module; voice
messages are specific to alarms on 1 to 8 1zones.
7. In case there is no MPV8 voice module on the main board or it was deactivated, the panel will report upon remote interrogation calls or to the follow me phone numbers only by
specific synthesis sounds.
Section [035] – Report and Download OPTIONS
When the system is within “main programming menu”, to establish the download options select section [035]. The 1 to 8 options will be displayed according to the table below:
Key
pressed to
toggle
option
KP-126Pz / KP-164Pz (LED
keypads)
Description
KP16LCD / KP16LCDL (LCD keypads)
Zone
LED
ON OFF 1
st
line message
2
nd
line message
Enabled Disabled
[1] 1
enabled
*
disabled Callback required
CallBackRq Enable k1 Disable k1
[2] 2
enabled
*
disabled Panel answers to remote PC calls
C612AnswPC Enable k2 Disable k2
[3] 3
enabled
*
disabled Automatic LOG transmission when LOG is 90% full
ARepPC90% Enable k3 Disable k3
[4] 4
enabled
*
disabled Report round OK at the end of round period
RepRoundAtEnd Enable k4 Disable k4
[5] 5
enabled
*
disabled Siren triggering upon ambush (user under duress)
SirOnAmbush Enable k5 Disable k5
[6] 6
enabled
*
disabled Siren triggering upon keypad lockout
SirOnKplockout Enable k6 Disable k6
[7] 7
Special alarms generated from keypad (Fire,
Maintenance, Medical emergency, Panic) report
Keypad address as 0 (for compressed Contact ID
compatibility)
RepKpdAddrAs0 Enable k7 Disable k7
[8] 8
Skip reporting to CS PGM activation by card
SkipRepPGMCard Enable k8 Disable k8
Note: The default programmed options are marked with *.
Press the [1] to [8] keys in order to turn the appropriate option enabled/disabled and the keypads will display activate/deactivate status of the
corresponding options.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6 confirmation beeps and the panel exits the [035]
programming section, waiting for a new command to enter another section or [#] key to exit the main programming menu.
Note: In case both “callback required” and “Panel answers to remote PC calls” options are selected, the control panel will answer to PC calls either after “double call” or after the number
of rings programmed in section [039]. Once the control panel answers to PC calls, the control panel and PC will verify each other the passwords (the control panel and PC identification codes
within upload/download, programmed in sections [091] and [092]) and, if the passwords are correct the control panel and PC will “close” the phone line. Then, the PC modem automatically will
pass into the auto-answer mode for control panel calls and the control panel will start to dial the “PC phone number” programmed in section [093]. While the control panel is calling back the “PC
phone number” the PC modem will “take” the phone line over and try to communicate with panel. The control panel and PC will verify again each other passwords and, if the passwords are
correct, the communication between the control panel and PC will be activated. If the communication between the control panel and PC was successfully activated, then the keypad buzzer of the
system will sound 6 confirmation beeps. After the control panel dialed the last digit of “PC phone number” it will wait for 20 seconds for the PC modem to answer. If the communication between