41
TonPGM1
002
TOnPGM2
002
Choose Sect:
1. If the option of “keypad lockout” after too many wrong codes was enabled within section [020], then the “keypad lockout counter” will be counting the successive attempts of entering wrong
access codes. In case the successive attempts of entering wrong access codes gets the value set in this section the keypad will lock for 7 minutes and all the keypad LEDs will fast blink. The
event will be memorized into the 800-event LOG, which can be uploaded and viewed onto PC by “EZcom C612 Software” and optionally a specific reporting code will be transmitted to CS, too
(if the digital communicator is enabled by programming and the appropriate reporting code is programmed within [058] or [069] section).
2. For the “keypad lockout counter” any value from 00 to 99 may be entered, but the panel will automatic adjust the introduced value by modulo 16 and will record the result in memory as
programmed value. If the result of adjustment is 0, then the panel will record the default value of “10”.
3. For any zone which allows auto shutdown the panel is counting the zone restore events and in case the number of zone restores gets the value set in this section, the respective zone will be
automatic “bypassed from swinger” for that arming period (or for that disarming period for 24h zones) until a new disarming (or arming).
4. For the “swinger shutdown counter” any value from 00 to 99 may be entered, but the panel will automatic adjust the introduced value by modulo 16 and will record the result in memory as
programmed value. If the result of adjustment is 0, then the panel will record the default value of “03”.
Section [042]: Number of voice or sound dialing sequences / Time of the Voice or Sound Reporting
Enter 2 groups of 2 digits, the first being the number of times the voice message (or the synthesis sounds) will be repeated for programmed phone numbers (01 to 99 sequences) and
the second 2-digit group being the time (01 to 99 seconds) of the voice reporting (or of the synthesis sounds).
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Remark: A voice/sound dialing sequence consists of sending the voice message (or the synthesis sounds) once to each of the programmed phone numbers (up to 4 follow me phone numbers).
After a voice dialing sequence was finished, the control panel will begin the next sequence similarly until the sequence number programmed in this section was over.
Note: For the “number of voice/sound dialing sequences” and “time of the voice/sound reporting” you can set even the value 00. Don’t program the value 00 for these parameters because
the voice message or the synthesis sounds will no longer be transmitted on the phone line!
Section [043]: Activation times for PGM1 to PGM6 defined as pulse types (001 to 255 seconds or minutes)
Activation times (001 to 255 seconds or minutes) for PGM1 to PGM6 defined as pulse types stand for number of the seconds or minutes, depending of appropriate option programming
in section [022], during which each pulse PGM type will be activated to GND.
After the first 3 digits were entered, the keypad buzzer will sound 3 beeps and 6 beeps after the last 3 digits. Then the panel exits the section and will wait for a new command.
Press [#] key instead of the corresponding 3-digit group if one of the 6 timings isn’t to be modified.
To exit the “main programming menu”, press [#] key.
No.of MPVSeq
02
TimeMPV
30
, type one 2 digit number
or
[#]
Choose Sect:
, type one 2 digit number
or
[#]
, type one 3 digit number
or
[#]
, type one 3 digit number
or
[#]
, type one 3 digit number
or
[#]
TonPGM3
002
TOnPGM4
002
, type one 3 digit number
or
[#]
, type one 3 digit number
or
[#]
TonPGM5
002
TOnPGM6
002
, type one 3 digit number