4. For the burglary siren timer” and fire siren timer” you can set even the value 00. Don’t program the value 00 for “burglary siren timer” and fire siren timer” because the siren
will no longer activate upon the “burglary” and fire” alarms!
Section [039]: Transmission Delay upon “AC power loss” (00 to 99 minutes) / Number of rings (01 to 99 rings)
While system is being within “main programming menu”, in order to establish the transmission delay upon AC power loss (01 to 99 minutes) and the number of rings, you have
to select section [039] and then enter 2 groups of 2 digits.
The transmission delay upon AC power (220Vac) loss is the time lapse after which the control panel will transmit this event to the “central station” (or the time lapse after which the
control panel starts the voice/sound transmitting of the event). If meanwhile the AC power is restored, the event reporting code and the voice message, too, are no longer
transmitted.
Ring number is the number of rings after that the control panel answers to the remote calls, the remote interrogation calls and/or the remote PC calls.
After the first 2 digits, the keypad buzzer will sound 3 beeps and after the next 2 digits, the keypad buzzer will sound 6 confirmation beeps and the panel exits the section,
waiting for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
1. If transmission delay upon “AC power loss” was set at 00, then the panel will transmit this event to the “central station” once it occurred (or the panel starts the voice/sound transmitting of
the event once it occurred).
2. The ring number programmed in this section is no longer considered in case “double call” option is set in section [035].
Section [040]: “Intellizone Time Window”
Enter 3 digits (001 to 255 seconds) in order to set the “Intellizone Time Window”.
The keypad buzzer will sound 6 confirmation beeps after the 3-digit group and the panel exits the section, waiting for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Note: For the “Intellizone Time Window” any value from 000 to 999 may be entered, but the panel will automatic adjust the introduced value by modulo 256 and will record the result in
memory as programmed value. If the result of adjustment is 0, then there will be no “Intellizone Time Window” and all zones in the system will respond as normal, even for some of them
their intellizone attribute were set as enabled!
Section [041]: “Swinger Shutdown Counter” / “Keypad Lockout Counter”
In order to establish the “swinger shutdown counter” and “keypad lockout counter”, enter 2 groups of 2 digits (0 to 15), the first 2-digit group being the “swinger shutdown counter”
and the second 2-digit group being the “keypad lockout counter”.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Notes:
Delay ACLoss
02
No.of Rings
10
, type one 2 digit number
or
[#]
Choose Sect:
, type one 2 digit number
or
[#]
, type one 3 digit number
or
[#]
SwingStDw Cnt
03
KpLockout Cnt
10
, type one 2 digit number
or
[#]
Choose Sect:
, type one 2 digit number
or
[#]

Related product manuals