EasyManua.ls Logo

Cerber C816 - Section [053]: Event Reporting Codes in 4 x2 Format regarding: Stay Arming by User; Stay Keyswitch Arming; Quick Stay or Instant Stay Arming; Partial arming; Fail to autoarm; Section [054]: Event Reporting Codes in 4 x2 Format regarding: “Disarming by User; Keyswitch Disarming; Remote disarming by PC; Timed Autodisarming; Timed Autoarming Stopping

Default Icon
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
Ev.codes S:055
00
Ev.codes S:056
0000000000
Ev.codes S:057
352140
5. The digit specific to "disarming by user” event will be used by the panel to generate the event code for transmission to the central station” in 4x2 formats (4 account digits + 2 event
digits). So, in order to get the 2 event digits, the panel will automatic add to this specific digit the corresponding digit of the user number (for all users from 15 to 45 the
identifying digit of user number will be either F” or modulo 16, according to the corresponding flag programming from section [032]).
Section [055]: Event Reporting Codes in 4x2 Format regarding: “Swinger-shutdown” zone bypassed / Zone Bypassed
Enter 2 digits (HEX digits may be used), one digit for each event.
The keypad buzzer will sound 3 beeps after the first digit and 6 beeps after the second one. Then the panel exits the section and will wait for a
new command.
To exit the “main programming menu”, press [#] key.
Note:
1. Second reporting code of zone bypassing will be transmitted to CS only upon arming, if there are in the system:
- Bypassed zones by the panel in case of partial arming and the respective zones are as interior type and/or
- Bypassed zones by the users using [*][3][User Code] or [BYPASS][User Code] commands.
2. If one event code should keep its value previously set, press [#] key instead of that corresponding digit.
3. If one event code isn’t to be reported to CS, the digit which corresponds to the event will be set as [0] value.
4. Each digit specific to “zone bypassed from swinger” and “zone bypassing” events will be used by the panel to generate the event codes for 4x2 transmissions to the “central station” (4
account digits + 2 event digits). So, for zone that generated events of the type: “zone bypassing” or “zone bypassed from swinger”, in order to get the 2 event digits, the panel will
automatic add to these specific digits the corresponding digit of the zone number (1 to 12/16).
Section [056]: Event Reporting Codes in 4x2 Format regarding: “Guardian Rounds started” / “Guardian Rounds
finished” /”Guardian Round OK”/ Guardian Round Failed” / “Ambush on Guardian Round”
Enter 5 groups of 2 digits (HEX digits may be used), one group for each reporting event.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last digit. Then the panel exits the section and will wait for a
new command.
To exit the „main programming menu”, press [#] key.
Notes:
1. If one event code should keep its value previously set, press [#] key instead of the corresponding group.
2. If one event code isn’t to be reported to CS, the 2 digits which correspond to the event will be set as [00] value.
3. In case of any 4x2 formats were set by programming, the panel will report to CS as follows:
- For the „starting/finishing the guardian rounds” by users using [*][9][user code][6 key] command, the control panel will transmit to CS the same specific reporting codes regarding
guardian rounds started” and „guardian rounds finished”, established in this section, indifferently of user number (users cannot be identified to CS in 4x2 formats, when they are
„starting/finishing the guardian rounds” by means of [*][9][user code][6 key] command).
- For „guardian round OK”, „guardian round failed” and „ambush on guardian roundevents, the panel will report to CS the same specific reporting codes established in this section,
indifferently of zone number (zones cannot be identified to CS in 4x2 formats in case of these events).
Section [057]: Event Reporting Codes in 4x2 Format regarding: “Burglary Alarm” / “Tamper Alarm” / “Panic Alarm”
/ “Fire Alarm” / “Medical Emergency Alarm” / “User under Duress (ambush)”
Enter 6 digits (HEX digits may be used), one digit for each reporting event.
The keypad buzzer will sound 3 beeps after each digit and 6 beeps after the last one. Then the panel exits the section and will wait for a new
command.
To exit the “main programming menu”, press [#] key.
Notes:

Related product manuals