51
E7E8000000
50EE5E
F7F8000000
1. If one event code should keep its value previously set, press [#] key instead of that corresponding digit.
2. If one event code isn’t to be reported to CS, the digit which corresponds to the event will be set as [0] value.
3. Each digit specific to each event will be used by the panel to generate the event code for transmission to the “central station” in 4x2 formats (4 account digits + 2 event digits). So, in
order to get the 2 event digits, to these specific event digits, the panel will automatic add:
- The corresponding digit of the user number (for all users from 15 to 45 the identifying digit of user number will be either “F” or modulo 16, according to the corresponding flag
programming from section [032]), in case of “user under duress” event;
- The corresponding digit of the zone number (1 to 12/16) for zone that generated events, of the type: “burglary alarm”/”tamper alarm”/”panic alarm”/”fire alarm”/”medical
emergency alarm”;
- The digit [0] for triggered from keypad events of the type: “panic alarm”/”fire alarm”/”medical emergency alarm” (triggered events by simultaneously pressing the corresponding
key combinations).
Section [058]: Event Reporting Codes in 4x2 Format regarding: “Keypad Lockout” / “Zone Alarm Restore” / “Tamper
Alarm Restore” / Keypad Tamper Alarm / Keypad Tamper Alarm Restore
Enter 5 groups, first of 2 digits and the last 4 groups of 1 digit (HEX digits may be used), one group for each reporting event.
The keypad buzzer will sound 3 beeps after the first 2-digit group and after all the 1-digit, and 6 beeps after the last digit. Then the panel exits the
section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Notes:
1. If one event code should keep its value previously set, press [#] key instead of the corresponding group.
2. If one event code isn’t to be reported to CS, the 2 digits which correspond to the event will be set as [00] value.
“Keypad lockout” code will be transmitted to CS when the keypad is locked for 7 minutes after too many wrong codes. The option of “keypad lockout” has to be also enabled
within section [020].
Section [059]: Event Reporting Codes in 4x2 Format regarding: “AC power loss” / “Low Voltage on Battery” / “Bell
Trouble” / “AUX overload” / “System time and date Not Programmed” (Power ON)
Enter 5 groups of 2 digits (HEX digits may be used), one group for each reporting event.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a new command.
To exit the “main programming menu”, press [#] key.
Notes:
1. If one event code should keep its value previously set, press [#] key instead of the corresponding group.
2. If one event code isn’t to be reported to CS, the 2 digits which correspond to the event will be set as [00] value.
Section [060]: Event Reporting Codes in 4x2 Format regarding: “AC power Restore” / “Restore Voltage on Battery” /
“Bell Trouble Restore” / “System time and date Reprogrammed”
Enter 5 groups of 2 digits (HEX digits may be used), one group for each reporting event.
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last one. Then the panel exits the section and will wait for a
new command.
To exit the “main programming menu”, press [#] key.
Notes:
1. If one event code should keep its value previously set, press [#] key instead of the corresponding group.