EasyManua.ls Logo

CEStronics CES OMEGA FLEX - Activating Release Mode

CEStronics CES OMEGA FLEX
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.9 Activating release mode
A locking device which is in release mode remains permanently coupled, i.e. the door can be
opened permanently without necessitating the use of any locking media.
Required master media:
l Release-Master
The Program-Master must first be authorised for the locking device on which it is to be
used
Procedure:
1. Hold the Release-Master before the reading field of the locking device.
After ca. 1 second, the following signal appears:
1x short green and 1x short beep
If the locking device already lights up green while the Release-Master is being read, but no
green flashing signal appears after one second, release mode is already active.
2. Remove the Release-Master from the reading field of the locking device.
The release mode is now active. Permanent access without locking media is now possible because
the coupling of the locking device is permanently engaged. The release mode has no time limit.
Altered signalling in release mode: In release mode, the locking device signals 1x long
green (instead of 1x short green) after reading from an authorised locking media.
Troubleshooting:
Signalling Reason Solution
A higher-priority opening mode is currently
active
b) Deactivate the opening mode with the
higher priority.
The Release-Master is not authorised. Authorise the Release-Master.
Signalling of OMEGA FLEX Locking devices Page 21 of 39
2 Signalling while using the master media

Other manuals for CEStronics CES OMEGA FLEX