1 Signalling during operation
1.1 Opening the locking device with a locking medium
Procedure:
1. Hold an authorised locking media for ca. 1 second in the reading field of the locking device
(maximum distance ca. 10 mm).
The following signal appears:
1x short green and 1x short beep
You can open the door by pressing the lever handle for a certain period. The length of the time
period depends upon the opening period set.
During the opening period no further locking media or master media are read. Only after
you hear that the coupling of locking device has disengaged, you can hold another locking
media in the reading field of the locking device.
Troubleshooting:
Signalling Reason Solution
The locking
media cannot be
read (No signal).
The locking media was not held close
enough to the reading field of the locking
device.
Hold the locking media longer in the
reading field of the locking device.
The reading field is shielded by metallic
materials.
Remove the metallic materials from the
reading field of the locking device.
Shortly before, another authorised locking
media was held in the reading field of
the locking device and the opening
period of the locking device has not yet
expired.
You can open the door without having to
have your locking media read.
The battery is empty. Replace the batteries
b) The locking media is defective. Have a new locking media issued by the
administrator of the OMEGA FLEX system.
Signalling of OMEGA FLEX Locking devices Page 3 of 39
1 Signalling during operation