2.1 Authorising System-Master
Each locking device of an OMEGAFLEX system must first become familiar with the System -
Master of the system so that the System-Master is authorised to authorise additional master
media for this locking device.
Each OMEGA FLEX system has only one System-Master. Through the system identification code
which is stored in the locking device and in the System-Master, it is ensured that only the System-
Master belonging to a given system can be authorised for the locking devices of that system.
For security reasons, you should authorise the System-Master on all locking devices.
If you are using the OMEGA Suite: Ensure that the System-Master has been read into the
OMEGA Client. As a result, it is automatically authorised for the locking device during the
initial reprogramming of the locking device.
Required master media:
l System-Master
Procedure:
1. Hold the System-Master for ca 1 second in the reading field of the locking device and then
remove it from the reading field.
The following signal appears:
1x short green and 1x short beep
Page 8 of 39
Signalling of OMEGA FLEX Locking devices
2 Signalling while using the master media