CG Drives & Automation,01-5326-01r5 Functional Description 117
Crane Communication [25Y]
Crane Communication delay time, starts counting when the
fault is gone. When the time delay has elapsed, the alarm
will be reset if the function is active.
Communication information
11.4.8 Serial Communication [260]
This function is to define the communication parameters for
serial communication. There are two types of options
available for serial communication, RS232/485 (Modbus/
RTU) and fieldbus modules (CANopen, Profibus,
DeviceNet, Modbus/TCP, Profinet IO, EtherCAT and
EtherNet/IP).
For more information see Chapter 9. page 71 and respective
option manual.
Comm Type [261]
Select RS232/485 [262] or Fieldbus [263].
Communication information
RS232/485 [262]
Press Enter to set up the parameters for RS232/485
(Modbus/RTU) communication.
25Y Crane Comm
Default: Off
Off 0 Off
1- 3600 1- 3600 1- 3600 s
Modbus Instance no/DeviceNet no: 43563
Profibus slot/index 170/212
EtherCAT and CANopen index (hex) 4deb
Profinet IO index 19947
Fieldbus format Long, 1=1s
Modbus format EInt
261 Com Type
Default: RS232/485
RS232/485 0 RS232/485 selected
Fieldbus 1
Fieldbus selected (CANopen, Profibus,
DeviceNet, Modbus/TCP, Profinet IO,
EtherCAT or EtherNet/IP)
Modbus Instance no/DeviceNet no: 43031
Profibus slot/index 168/190
EtherCAT and CANopen index (hex) 4bd7
Profinet IO index 19415
Fieldbus format UInt
Modbus format UInt
NOTE: Toggling the setting in this menu will perform a
soft reset (re-boot) of the Fieldbus module.
262 RS232/485