27
o
u
t
d
o
o
r
b
l
o
w
e
r
f
a
n
d
o
o
r
b
l
o
w
e
r
f
a
n
TP2
defrost time over 15 MIN or TP2 >15° C
Tr
c
o
m
p
r
e
s
s
o
r
Sequence chart in defrosting mode
end defrost
start-up
shutdown start-up
shutdown
start-up
start-up
start-up
shutdown
defrost
our-way
valve
d
o
o
r
b
l
o
w
e
r
f
a
n
start-up
start-up
start-up
start-up
shutdown
shutdown
outdoor
blower fan
compressor
start defrost
Dehumidification
Dehumidification running is to eliminate the water vapor in the air by using the cool circulating capacity, but the
dehumidification will not decrease the indoor temperature in great deal. The air conditioner automatically repeats on
and off circulation according the room temperature, which is shown in the following figure.