The room is too large ;the
window or door is not closed.
Close the window and door
Too many persons or heat
source in room.
The installed position of outdoor
unit isn’t good. Have insolation
or not good in ventilation.
The installed position of indoor
unit isn’t good. Bad in air
circulation.
The air filter is dirty or blocked.
Check capillary tube, strainer
etc. repair or replace them.
refill up refrigerant after
checking the leak source.
The set temperature is too
high .
reduce the set temperature.
The condenser blocked by dust
or others.
Too much quantity of
refrigerant.
take the redundant refrigerant
out.
Blockage in airinlet or air outlet.
Air mixed in refrigerant.
High outdoor temperature.
The indoor or outdoor fan motor
is running slow
Change this indoor or outdoor
fan motor
The compressor suction or
venting capability is very poor
Four-way valve slight mixes up
The fan doesn’t run (motor or
capacitor of fan failed, Poor
contact for the line of capacitor,
line fault. The motor relay and
drive circuit is fault)
Check. Repair and replace.
The compressor doesn’t
work(the voltage is too
low ,overload, wiring error. The
compressor failed. The
capacitor of compressor failed.
the capacity of electric fence isn’t
enough. )
Check. Repair and replace.