E10
Current output type:
Output specification 4 to 20mA DC
Load resistance 600Ohm or less
SSR drive pulse output type:
Pulse cycle Approx. 1 to 180 seconds
Output specification ON 12V DC ±20%
(load current 21mA or less)
OFF 0.8V DC or less
Voltage output type:
Output specification 0 to 10V DC
Output resistance Approx. 10Ohm
Load resistance 50kOhm or more
Specification with 2 outputs:
Output type Any combination between ON-OFF pulse output,
current output and voltage output is possible.
Insulation Non-isolated between 2 outputs (ON-OFF pulse
output type excluded)
Control system PID, split
General specifications
Rated power voltage 100-240V AC (±10%), 24V AC/DC (±10%)
Rated power supply frequency 50/60Hz (±2%)
Maximum power consumption:
100 to 240V AC (without option)
DB630 100V AC: 4VA, 240V AC: 5VA
DB650 100V AC: 4VA, 240V AC: 6VA
DB670 100V AC: 4.5VA, 240V AC: 7VA
100 to 240V AC (with option)
DB630 100V AC: 5VA, 240V AC: 7VA
DB650 100V AC: 7VA, 240V AC: 10VA
DB670 100V AC: 9VA, 240V AC: 12VA
24V AC/DC (without option)
DB630 24V AC: 3VA, 24V DC: 2W
DB650 24V AC: 4VA, 24V DC: 3W
DB670 24V AC: 4.5VA, 24V DC: 3.5W
24V AC/DC (with option)
DB630 24V AC: 4VA, 24V DC: 3W
DB650 24V AC: 7VA, 24V DC: 5W
DB670 24V AC: 8VA, 24V DC: 6W
External dimensions
DB630 48(W)×48(H)×88(D)
(Depth from panel surface is 80)
DB650 48(W)×96(H)×73(D)
(Depth from panel surface is 65)
DB670 96(W)×96(H)×73(D)
(Depth from panel surface is 65)
Weight
DB630 (Without option) Approx. 120g
(With option) Approx. 135g
DB650 (Without option) Approx. 150g
(With option) Approx. 230g
DB670 (Without option) Approx. 240g
(With option) Approx. 330g
Terminal screw M3.0
Normal operating condition
Ambient temperature -10 to 50°C
(-10 to 40°C for close installation)
Maximum ambient humidity (ambient temperature -10 to 31°C)
90% rh (no condensation)
Maximum ambient humidity (ambient temperature 31 to 50°C)
90 to 50% rh (no condensation)
*Decreases linearly from 90% rh at 31°C, or to 50% rh at 50°C.
Minimum ambient humidity 20%rh
Power voltage:
100 to 240V AC 90 to 264V AC
24V AC/DC 21.6 to 26.4V AC/DC
Power supply frequency 50/60Hz±2%
Mounting orientation Backward/forward ±10°, laterally ±10°
Installation height Below 2000m
Vibration 0 m/s
2
Shock 0 m/s
2
Installation condition Panel mounting (space above and below)
External noise None
Ambient temperature variation ratio 10°C/hour or less
Transport condition
Ambient temperature -20 to 60°C
Ambient humidity 5 to 95% rh (no condensation)
Vibration 4.9m/s
2
or less (10 to 60Hz)
Shock 392m/s
2
or less (under factory packing
condition)
Safety and EMC standards (UL/cUL conformity)
EMC Directive EN61326-1 conformity (CE/ UKCA) ClassA
* Indication or output value varies by the
amount equivalent to ±10% of FS or ±2mV,
whichever is larger, during testing.
Safety EN61010-1 conformity (CE/ UKCA)
EN61010-2-030 conformity (CE/ UKCA)
UL61010-1 certification (UL)
UL61010-2-030 certification (UL)
CAN/CSA C22.2 No.61010-1 certification (cUL)
Overvoltage category: II
Pollution degree: 2
Environmental regulations RoHS (CE/ UKCA)
Environmental regulation standards:
EN IEC63000 conformity
(Monitoring and control instruments including
industrial monitoring and control instruments.)
File No. E214646 (UL)
Event output (option)
Output point
Mechanical relay DB630
2 points maximum
DB650
4 points maximum
DB670
4 points maximum
Open collector 5 points maximum
Output capacity (mechanical relay output):
Contact capacity Resistive load 240V AC 3A, 30V DC 3A
Inductive load 240V AC 1.5A, 30V DC1.5A
Minimum load 5V DC 10mA
Output capacity (open collector output):
Contact capacity 24V DC 50mA
Heater disconnection detection (option)
Function Measure heater current using an external current transformer
(CT) to detect disconnection.
Input point 1 point
CT input range 0.0 to 65.0mA AC (50/60Hz)
Heater current measuring range 5.0 to 50.0A AC
Measurement category None
Input signal 5.0-50.0A(5060Hz)
Accuracy ±5.0% of FS ±1digit
*Designated CT: produced by U.R.D. Co., LTD. "CTL-6-S-H"
LTA-P207 (800 turns, Hole diameter 5.8mm) sold separately
Transmission signal output (option)
Output point 1 point
Output signal 4 to 20mA DC (load resistance 400Ohm or less)
0 to 10V DC (load resistance 50kOhm or more)
Accuracy ±0.3% of FS ±1digit
Output updating interval Approx. 0.1 seconds
Insulation Non-isolated between the adjustment output and 2
(ON-OFF pulse output type excluded)
Remote signal input (option)
Input point 1 point
Input signal 4 to 20mA DC (input resistance approx. 50Ohm)
0 to 10V DC (input resistance approx. 100kOhm)
Maximum allowable input DC current ±30mA or less
±1.5V DC or less
DC voltage ±20V DC or less
Accuracy ±0.3% of FS ±1digit
Sampling rate Approx. 0.1 seconds
External signal switch R/L (Remote/Local)
External signal input (option)
Input point DB630 5 points maximum, COM shared
DB650 7 points maximum, COM shared
DB670 7 points maximum, COM shared
Input signal No voltage contact
External contact capacity 5V DC 2mA
Function Constant value operation RUN/READY switch,
AUTO/MAN switch, preset manual, timer 1, timer 2,
alarm event reset, execution No. selection,
program/constant value operation switch, program
operation RUN/STOP switch, program operation
ADVANCE, program operation RESET, program
pattern selection

Related product manuals