E12
Item Range Default
MODE 5
Linear decimal point :No decimal point
:1-digit after decimal point□□to
:4-digit after decimal point
□
Linear scale zero
to □□
□
Linear scale span
to
Sensor correction to [°C] □□
Digital filter to [sec] □□□
SV limiter L to [°C]
SV limiter H to [°C]
Display decimal point :No decimal point
:1-digit after decimal point□□to
:4-digit after decimal point
□
MODE 6
Pulse cycle to [sec] □□□
Feedback zero
to [%] □□□
Feedback span
to [%] □
Feedback deadband
to [%] □□□
PID deadband/
output deadband
to [%] □□□
Control action :Heating control
:Cooling control
Output preset to [%] □□
Output variation limiter L
to [%]
Output variation limiter H
to [%] □
PV abnormal output to [%] □□□
Preset manual to [%] □□□
Operation on power ON :READY status/program operation
RESET
:Operation right before previous
power-OFF
Control algorithm :Position PID control
:Velocity PID control
:Z control
or
Feedforward :Without feedforward calculation
:With feedforward calculation
□□
MODE 7
Output 2 control system □ :PID control or Z control
:Split control
□□
Output 2 P
:Two-position control
to [%]
□□□
Output 2 I
t o [sec] □□□
Output 2 D
t o [sec] □□□
Output 2 gap
to [%] □□□
Output 2
PID deadband/
output deadband
to [%] □□□
Output 2 control action :Heating control
:Cooling control
Output 2 output preset
to [%] □□□
Split Direct
to [%] □□□
Split Reverse to [%] □
Output 2 pulse cycle to [sec] □□□
Output 2 output limiter L
to [%] □□□
Output 2 output limiter H
to [%] □
Output 2 variation limiter L
to [%]
Output 2 variation limiter H to [%] □
Output 2 preset manual to [%] □□□
MODE a
Communication protocol
□□ :MODBUS RTU
:MODBUS ASCII
:Private
□□
Communication function □□ :Host communication
:Digital transmission
:Digital remote input
□□
Instrument No. to □□□□
Communication transmission
rate
:4800bps :9600bps
:19200bps :38400bps
□
Communication character :7-bit/even parity/stop bit 1
:7-bit/even parity/stop bit 2
:7-bit/odd parity/stop bit 1
:7-bit/odd parity/stop bit 2
:8-bit/no parity/stop bit 1
:8-bit/no parity/stop bit 2
:8-bit//even parity/stop bit 1
:8-bit/even parity/stop bit 2
:8-bit/odd parity/stop bit 1
:8-bit//odd parity/stop bit 2
□□
Digital transmission type □ :Digital SV transmission
□ :Digital PV transmission
□ :Digital output 1 transmission
:Digital output 2 transmission
:Digital output FB transmission
□□□
Digital transmission cycle :100msec cycle
:200msec cycle
□ :1 sec cycle
□
Communication display :No communication display
□ :With communication display
□□
Item Range Default
MODE b
Transmission type :SV transmission signal output
□ :PV transmission signal output
□ :Output 1 transmission signal output
:Output 2 transmission signal output
:FB transmission signal output
□□□
Transmission scale zero to [°C]
Transmission scale span to [°C]
MODE c
Remote/local
switching
:Local SV operation
:Remote SV operation
Remote SV shift to [°C] □□
Remote SV filter to [sec] □□□
Tracking at
switch to local
:Function OFF
□ :Tracking function ON
□□
Remote SV scale zero to [°C]
Remote SV scale span
to [°C]
Cascade γ
to □□
Cascade β to □□□
MODE d
External input 1 □□ :Function OFF
:RUN/READY switch
:AUTO/MANUAL switch
:Preset manual
:Timer 1
:Timer 2
:Alarm event reset
:Execution No. selection 1 (Bit0)
□ :Execution No. selection 2 (Bit1)
:Execution No. selection 4 (Bit2)
□ :Execution No. selection 8 (Bit3)
:Program/constant value operation switch
□ :Program operation RUN/STOP
□ :Program operation ADVANCE
:Program operation RESET
:Program pattern 1 (Bit0)
:Program pattern 2 (Bit1)
:Program pattern 4 (Bit2)
□□
External input 2
External input 3
External input 4
External input 5
External input 6
External input 7
MODE t
Key lock □□ :No key lock
:Operation parameter keys locked
□□ :All parameter keys locked
□□
Operation initial screen □□ :PV/SV display screen
:PV/step time display screen
□ :PV/OUT1 display screen
:PV/OUT2 display screen
□□□
Operation screen SV display □□ :SV display
:Blank display
:Multi-display
Bar display □□ :No display
□ :Output 1 display
□ :Output 2 display
□□□ :CT measured value display
□□□ :FB measured value display
□ :Step remaining/elapsed time display
□□
Parameter storing :Backup function OFF
□ :Backup function ON
□□□
Parameter initialization :No initialization
:Initialization executed
□□
Port switch :USB engineering port
□ :IR engineering port
□□
Multi-output switch :Normal output
:ON-OFF pulse output
:Analog output
□□ :SSR drive pulse output
Calculation RESET at READY □ :Calculation continue
:Calculation RESET
□
Anti-reset
・
wind up L to□□ [%]
Anti-reset
・
wind up H □□□ to [%]
□
32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632
PHONE: +81-3-3956-2171
FAX: +81-3-3956-0915
E-mail: inter@chino.co.jp
Website: https://www.chino.co.jp
July. ’21
DB6-61-6