Installation panel
155.5
303
379
202.5
232.5
16
48
405
273
362
Right & outer
side of breaker
20
NA1-3200x/NA1-3200xN Drawout-type, horizontal, rear connection
NA1-3200x/NA1-3200xN Fixed-type
10 97 175
391
112
a
107.5
528(4P)
413(3P)
232.5
352
465(3P)
580(4P)
37
70
42.5
258
439
115
104
100
N pole
40
50
20
125 125
16×Φ13
92.5
In A
~
2000 2500
3200
a mm
20
30
C
45(Disconnected position)
11×17
440(4P)
325(3P)
70
Φ14
175
33
Φ11
Right & outer side of breaker
21
258
13
493(4P)
378(3P)
352
515(4P)
400(3P)
11 11
290
389
150
a
a
112
5560
115
402
4×Φ12
515(4P)
400(3P)
150
362
269
28.5
311
405
2
50
18min
211
69.5
Zero arcing covering
ferreous material
Opening hole on panel
Installation panel
Installation hole on
Right & outer side of breaker
Installation hole
on Right & outer
side of breaker
In A
2000~2500
3200
a mm
20
30
115
40
86
40
15
115
32 13×Φ
N pole
115 115
72
115
40
86
N pole
15
16 13×Φ
40
115 115
96
32
115 115115
86
N pole
18.5
12 13×Φ
50
96
horizontal connection(Default Configuration)
L type vertical connection
horizontal connection shorten busbar
8×Φ4
202.5
D
C
C
C
D
C
94
Opening hole on panel
Installation panel
155.5
303
379
202.5
232.5
16
48
405
273
362
Right & outer
side of breaker
20
Installation panel
155.5
303
379
202.5
232.5
16
48
405
273
362
Right & outer
side of breaker
20
NA1-3200x/NA1-3200xN Drawout-type, vertical, rear connection
NA1-3200x/NA1-3200xN Drawout-type
In A
~
2000 2500
3200
a mm
20
30
10 97 175
391
20
40
94
8×Φ13
126
100
50
100
528(4P)
413(3P)
232.5
352
465(3P)
580(4P)
37
70
42.5
258
439
2×11×17
440(4P)
325(3P)
70
Φ14
175
33
Φ11
a
115
N pole
115 115 102.5
45(Disconnected position)
C
Right & outer side of breaker
Opening hole on panel
In A
2000~2500
3200
a mm
20
30
2×11×17
440(4P)
325(3P)
70
Φ14
175
33
Φ11
528(4P)
413(3P)
580(4P)
465(3P)
352
112
92
23
97 175
391
536
37
42.5
70
258
439
10
232.5
45(Disconnected position)
Right & outer side of breaker
Opening hole on panel
horizontal connection(Default Configuration)
L type vertical connection
horizontal connection shorten busbar
32 13×Φ
120 125125
40
100
40
17
115
100
120 125125
50
100
N Pole
25
16 13×Φ
50
115 125 125 92.5
30.5
14
25
100
75
16 13×Φ
92.5
N Pole
a
a
C
C
C
D
C
D
104
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
15
Right & outer side of
insulation panel
Right & outer side of
breaker
C
NA1
Air Circuit Breaker
P-052
P-051
NA1
Air Circuit Breaker
11 4×Φ
11 4×Φ
11 4×Φ