IRIS Touch Engineering Manual Version 1.4 Page 39 of 40
Safety
Care should be taken when connecting telecommunications equipment to ensure only like interfaces are connected
to avoid safety hazards.
SELV:
SELV (Safety Extra-Low Voltage) is defined as a secondary circuit which is so designed and protected that
under normal and single fault conditions the voltage between any two accessible parts does not exceed a
safe value (42.4V peak or 60V dc maximum)
The interfaces on the IRIS Touch have the following safety classifications:
Power Interface: SELV for connection to a DC supply
Inputs: SELV for connection to alarm output pin.
Conformance
European Directives
The IRIS Touch complies with the following European Directives:
1999/5/EC (Radio & Telecoms Terminal Equipment Directive)
2006/95/EC (Low Voltage Directive)
2004/108/EC (Electromagnetic Compatibility Directive)
EN50131, EN50136 (VdS Certified)
The dialler is compliant with the requirements of European Standards:
EN50131-1: 2006 & EN50131-10: 2014
EN50136-1: 2012 & EN50136-2: 2013
Security Grade 4
ATS-SP6 over Ethernet, ATS-SP5 over GPRS/3G, ATS-DP4 (IRIS Touch 640NG)
Environmental Class II
EN54-21 CPR (VdS Certified)
EN54-21 CPR fire approved