High Power DC Electronic Load 63200 Series Operation & Programming Manual
7.2.2 COMMunicate Sub-system
COMMunicate
:ADDRess
:GPIB
:RS485
:SERial
:BAUD
:BITS
:PARity
:SBITs
COMMunicate:ADDRess:GPIB
Description Set the GPIB address
Syntax COMMunicate:ADDRess:GPIB <NR1>
Parameters 1 – 30
Example COMM:ADDR:GPIB 16
Query Syntax COMMunicate:ADDRress:GPIB?
Return Parameters <NR1>
Query Example COMM:ADDR:GPIB? Return GPIB address.
Return Example 16
COMMunicate:ADDRess:RS485
Description Set the RS485 address
Syntax COMMunicate:ADDRess:RS485 <NR1>
Parameters 1 – 5
Example COMM:ADDR:RS485 5
Query Syntax COMMunicate:ADDRress:RS485?
Return Parameters <NR1>
Query Example COMM:ADDR:RS485? Return RS485 address.
Return Example 5
COMMunicate:SERial:BAUD
Description Set the baud rate
Syntax COMMunicate:SERial:BAUD <NR1 | CHAR>
Parameters 0 | BAUD_48, 1 | BAUD_96, 2 | BAUD_192,
3 | BAUD_384, 4 | BAUD_576, 5 | BAUD_1152
Example COMM: SER:BAUD 5
COMM: SER:BAUD_1152
Query Syntax COMMunicate:SERial:BAUD?
Return Parameters 0 | 1 | 2 | 3 | 4 | 5
Query Example COMM:SER:BAUD? Return RS232 baud rate.
Return Example 5 ( BAUD_1152 )