CHRYSLER SERVICE MANUAL
AIR CONDITIONING^157
b.
Test strainer-drier and replace if required
as outlined in Paragraph 6.
c. Check super heat as outlined in Paragraph
26.
Replace valve if faulty.
43.
TESTING FOR LEAKS WITH LEAK
DETECTOR (For Diagnosis)
Where a system has been found to be low on
refrigerant or following repairs on system that
necessitated opening of a connector, it is nec-
essary to test for leaks and tighten connectors
or make repairs as required before system is
charged and put in operation* If system has
been discharged for making repair or to elimin-
ate moisture, system must be evacuated before
partially charging for a leak test.
a. Partially charge system with refrigerant
as outlined in charging system with Freon 12,
Paragraph 10 and proceed as follows:
This is necessary only where refrigerant sup-
ply in system is very low or where system has
been evacuated.
b.
Operate engine at 1200 rpm with blower
switch turned to "High". Discharge refrigerant
slowly through gauge manifold center fitting
until bubbles appear in sight glass. Charge sys-
tem with refrigerant as outlined in Paragraph
10.