460—CHRYSLER C-300B
CHRYSLER SERVICE MANUAL
3.
REAR AXLE DATA AND SPECIFICATIONS, CONTD
•OPTIONAL RATIOS AVAILABLE
3.07 (40-13), 3.36 (37-11), 3.54 (39-11), 3.73 (41-11), 3.91 (43-11), 3.9 (39-10)
4.0 (40-10), 4.1 (41-10), 4.3 (43-10)
4.56 (41-9), 4.89 (44-9)
4.
BRAKES
The Brakes are the same design as used on
all models.
5. CLUTCH
The Clutch is the same design as used on Model
C-71.
6. COOLING SYSTEM
The Cooling System is the same design as used
on Model C-72. For servicing, refer to the
Cooling System, Section V.
7. ELECTRICAL SYSTEM
The Electrical System is identical with that
used on Model C-72, with exceptions listed in
the Data and Specifications which follows:—
8. ELECTRICAL SYSTEM—DATA AND SPECIFICATIONS
BATTERY C-300B
Voltage 12 volts
Capacity 78 plate, 70 ampere—hour
Ground Terminal Negative
STARTING MOTOR
Model MDF-6001
No.
of Poles and Field Coils 4
Brushes 4
Drive Solenoid Shift, Positive Engagement
Brush Spring Tension (New Brushes) 42 to 53 ozs.
End Play .005" to .030"
Free Running Test 3200 RPM min. 60 amps. @ 10 volts
Stall Torque Test 6.5 lbs. min. 240 amps. @ 4 volts
Solenoid Switch:—
Pull-In Coil Draw 28.6 to 32.9 amps. @ 6 volts
Hold-In Coil Draw 10.2 to 11.8 amps. @ 6 volts
Pinion Adjustment
(Clearance Between Pinion and Stop) %f to
M^—MA
GENERATOR
Model
Standard (GJC-7002B; 1642002) Up to
(GJC-7002A; 1642002) After
With Power Steering (GJC-7003A; 1642005) Up to
(GJC-7003C; 1642005) After
With Air Conditioning (GJC-7006A; 1642009) or (GJC-7006B; 1642009) or
(GHM-6004C; 1704265)
With Power Steering and
Air Conditioning (GJC-7003A; 1642005) or (GJC-7003C; 1642005) or
(GHM-6003B; 1704265)
Rotation Clockwise at Drive End
Voltage 12 volt
Rated Output 30 amperes
Ground Polarity Negative
MyMopar.com