SCHEDA DI COLLAUDO TEST SHEET
ERMO 482 RX NUMERO DI SERIE
SERIAL NUMBER:
Cliente/Customer
Indirizzo/Address
Barriera /Barrier N°
(*) misura può essere effettuata anche con lo strumento STC 95
(*) It is possible to make the measure also by the STC 95
OSSERVAZIONI DELL’INSTALLATORE – INSTALLER COMMENTS
Data installazione/Installation date
Firma Installatore/Installer Signature
VALORI MISURATI SUL RICEVITORE MEASURED VALUES ON THE RECEIVER
MISURE
MEASUREMENTS
VALORI TIPICI
STANDARD
VALUES
VALORI MISURATI
MEASURED VALUES
INSTALLAZIONE
INSTALLATION
MANUTENZIONE
MAINTENANCE
1
TENSIONE DI ALIMENTAZIONE, MISURATA TRA I
PIN 4 - 6 DI J1(PIN4 = GND). (*)
SUPPLY VOLTAGE, MEASURED BETWEEN PINS
4 - 6 OF J1(PIN4 = GND). (*)
13,8 VDC 10%
2
TENSIONE DI ALIMENTAZIONE INTERNA
MISURATA TRA IL PIN 12 DI J1 E GND (*)
INSIDE SUPPLY VOLTAGE MEASURED BETWEEN
PIN 12 OF J1 AND GND (*)
5 VDC 10%
3
VERIFICA SEGNALE RIVELATO, MISURATA CON
LO STRUMENTO STC 95.
SIGNAL DETECTED VOLTAGE MEASURED BY
STC 95.
6 VDC 10%
STABILE
STEADY
4
TENSIONE DI RAG, MISURATA TRA IL PIN 14 DI J1
E GND. (*)
AGC VOLTAGE MEASURED BETWEEN PIN 14 OF
J1 AND GND. (*)
2,5 6 VDC
5
TENSIONE DI SOGLIA MISURATO TRA IL PIN 8 DI
J1 E GND.(*)
THREESHOLD VOLTAGE MEASURED BETWEEN
PIN 14 OF J1 AND GND. (*)
0.25 6.5 VDC
6
CANALE DI MODULAZIONE SELEZIONATO
MODULATION CHANNEL SELECTED
-
Ch 1
Ch 2
Ch 3
Ch 4
Ch 1
Ch 2
Ch 3
Ch 4