© CIAS Elettronica S.r.l. Ed. 1.0
Installation Handbook page 51 of 59 MANTA 50 – 80
56K Modem
Centre:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at+ms=9,1,9600,9600 Make a connection only at 9600 bps.
at\n3 Error correction V.42 LAPM/MNP.
ate0 Disable echo of controls..
at&w Store parameters..
Plant:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at+ms=9,1,9600,9600 Make a connection only at 9600 bps.
at\n3 Error correction V.42 LAPM/MNP.
ats0=1 Automatic reply after one ring.
ate0 Disable echo of controls..
at&w Store parameters..
Trust communicator 56K ESP
Centre:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at\n3 Error correction V.42 LAPM/MNP.
ate0 Disable echo of controls..
at&w Store parameters..
Plant:
at&f Load default parameters.
atx3 Engaged tone detection.
at%c3 Compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at\n3 Error correction V.42 LAPM/MNP.
ats0=1 Automatic reply after one ring.
ate0 Disable echo of controls..
at&w Store parameters..
MODEM CIAS 9600
Plant:
at&f Load default parameters.
ats0=1 Automatic reply after one ring.
at%c0 No compression MNP5 &V.42 bis.
at%e0 Auto-retrain disabled.
at\n5 Error correction MNP.
ate0 Disable echo of controls..
at&w Store parameters..
Note: the CIAS 485/9600 modem accept the serial line RS485, without the cable cross
connections and the conversion RS485/RS232.