EasyManua.ls Logo

cias SIOUX PRO 2 - Page 49

cias SIOUX PRO 2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© CIAS Elettronica S.r.l. Ed 1.1
Installation Manual Page 49 of 51 Sioux Pro 2
With this solution, the following cable is required:
- Cable between SiouxPro2-Line and distribution box
SiouxPro2-Line Line 1 or 2
Junction Box
Terminal
Terminal function
Wires Colour
Junction Box Functions
1
Power supply 27,6 Vcc
Green
Power supply 27,6 Vcc
1
Power supply 27,6 Vcc
White/Blue
Power supply 27,6 Vcc
2
GND
White/Orange
GND
2
GND
Orange
GND
2
GND
White/Green
GND
2
GND
Blue
GND
3
RS485 - High Line LH
Brown
RS485 High Line LH
4
RS485 - Low Line LO
White/Brown
RS485 Low Line LO
5
Shield
Shield
Shield
REMARKS:
- Connect White/Orange, Orange, White/Green and Blue wires together, to terminal 2
(GND) of the SiouxPro2-Line terminal block
- Connect Green and White/Blue wires together, to terminal 1 (27,6 Vcc) of the
SiouxPro2-Line terminal block
- Cable between junction box and first Sioux-Slave-Pro2
REMARK Using only precabled cable, check that colors correspond to numbering of
RJ45 connector’s pin
Pin
RJ45
1
st
Slave-Pro2 Connector
Functions
Wires Colour
Functions Junction box
1
GND
White/Orange
GND
2
GND
Orange
GND
3
GND
White/Green
GND
4
GND
Blue
GND
5
Power supply 27,6 Vcc
White/Blue
Power supply 27,6 Vcc
6
Power supply 3.3 Vcc
Green
Do not connect
7
RS485 - Low Line LO
White/Brown
RS485 - Low Line LO
8
RS485 - High Line LH
Brown
RS485 - High Line LH
Shield
Shield
Shield

Related product manuals