2-1-2 Location of the heat pump
The installer must check the following points before handling, placing or connecting the unit:
- The unit is intended for use outdoors, near a building, on a deck/patio or in a garden.
Although it is rain resistant, it may be installed under a shelter with adequate ventilation on all four sides.
If you plan on heating more than cooling, place the unit in a sunny location. If you plan on heating only a little, face the unit north-
wards.
- The ground or surface on which the unit is placed must be strong enough to support the weight of the unit.
- Position the unit above the average snow depth for the region where the unit is installed.
- The unit must be perfectly level.
- Leave sufficient room around the unit to allow easy access for servicing and maintenance.
- Nothing should obstruct the free flow of air over the air- cooled heat exchanger (
suction and discharge).
Noise level: our units are designed to be quiet when in operation. However, as soon as you begin designing your system, you
should take into consideration the outdoor environment to estimate the radiated noise and the building type to estimate the noise
transmitted through the air and by solid materials (
vibrations).
If in doubt, have an analysis performed by an acoustical engineer.