WELDSKILL 100, 135, 150 MIG
3-14
Installation
3.18 Setup for WeldSkill 135 Mig with Gasless MIG Wire
WARNING
Before connecting the work clamp to the work and inserting the electrode wire in the Mig Torch
make sure the Mains power supply is switched off.
CAUTION
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the
Welding Power Source.
NOTE
Refer to the set up guide located on the inside of the wirefeed compartment door.
WORK
WORK CLAMP
ARC
240V AC POWER SOURCE
Polarity Terminal
Knobs
Cable to Work
Lead (Black Cable)
Cable to MIG
Torch (Red Cable)
Art # A-09003_AB
Connection for FCAW (reverse polarity)
Figure 3-14: Gasless Set-up for WeldSkill 135 MIG