WELDSKILL 100, 135, 150 MIG
5-6
Service
9 Gas flow continues
after the torch trigger
switch has been
released.
Gas Solenoid Valve has
jammed open due to
impurities in the gas or
the gas line (150 Mig
only).
Have an Accredited CIGWELD Service
Agent repair or replace Gas Solenoid Valve.
10 Wire does not feed
when torch trigger
depressed
A Faulty trigger switch /
lead
A Repair or replace Torch / trigger lead
B Fuse on Printed Circuit
Board is blown
B Have an Accredited CIGWELD Service
Provider investigate the fault.
C Printed Circuit Board
Faulty
C Have an Accredited CIGWELD Service
Provider investigate the fault.
11 Wire continues to
feed when torch
trigger released
A Torch trigger leads
shorted
A Repair or replace Torch / trigger lead
B Printed Circuit Board
Faulty
B Have an Accredited CIGWELD Service
Provider investigate the fault.
12 OVERHEAT Indicator
is illuminated
Power Source Over Heat
Protection circuit has
operated
Cease welding and allow Power Source to
Cool for 10 minutes. Over Heat lndicator
will extinguish when the Power Source has
cooled sufficiently.
Table 5-4
5.07 Key Spare Parts
Cigweld Part Number Description
W4012900 Feed Roll 0.6/0.8mm, 100/135/150 Mig
W4012901 Feed Roll 0.8/1.0mm, 100/135/150 Mig
W4012902 Feed Roll 1.0/1.2mm, 100/135/150 Mig
W4013000 Mig Torch, 100/135 Mig
W4013100 Mig Torch, 150 Mig
W7004600 PCB Assembly, 100/135/150 Mig
W7004601 Wire Drive Assembly, 100/135/150 Mig
W7004602 Rotary Output Voltage Switch, 135/150 Mig
W7004603 Fan Assembly, 100/135/150 Mig
W7004604 Gas Solenoid Valve, 150 Mig
W7004605 Rectifier Assembly, 130/150 Mig
7977159 Dinse Panel Socket 25mm 150 Mig
210254 WeldSkill Argon Regulator/Flowmeter
Table 5-5