12
SYSTEM STATUS BUTTON: Press sequentially to cycle through the
following information on the LCD Display.
1. Pool temperature (xx degrees Fahrenheit or Celsius)
2. Cell voltage (typically 21.0 to 27.0 volts when chlorine is being
generated, otherwise 16-31V)
3. Cell current (typically 2.50 to 7.80 amps when chlorine is being
generated, otherwise 0 amps during normal rest cycles, a
hyphen preceding number indicates normal polarity reversal.)
4. Selected Output Level ("0 Percent" to "100 Percent" depending
on dial position or Super Chlor setting)
5. Instant Salinity reading ( -xxxx ppm or -x.xx grams/Liter, a
hyphen preceding number indicates normal polarity reversal.)
6. System ID
7. Software revision level
8. Cell Version
On the 9th push of the button the display will revert back to the default
Average Salinity display. The default display will also be restored any
time the button is not pushed for 30 seconds.
If Metric temperature (Celsius) or salinity (grams per liter) units are
preferred, push the System Status button to display the units you wish
to change (for example, press once to display temperature). Move the
SUPERCHLOR switch from AUTO to ON and back to AUTO. The units
displayed will instantly change to degrees Celsius. Repeat this process to
switch back to Fahrenheit.
TIP: When first installed, this reading may display the last salinity
readings taken at the factory. This average will begin to update with
your pool's operation over the first 24 hours.
TIP: As mineral scaling builds up in the cell after regular use, the system
may temporarily display an artificially low salinity level. After fully
cleaning your Cell, it will begin to detect salinity normally again.