Value Description
Use OCPP time
synchronization
YES: Synchronization of date and time -> Enabled.
NO: Synchronization of date and time -> Disabled.
NOTE: Date and Time is sent from backend on each heart-
beat response.
Compress OCPP
messages
YES: Compress messages between Charge point and back-
end -> Enabled.
NO: Compress messages between Charge point and backend
-> Disabled.
NOTE: Before enabling this option consult to your backend
administrator if central system allows this function.
Energy for Start/Stop
transaction
PARTIAL: Consumed value of energy by the vehicle sent be-
tween start and stop.
TOTAL: actual count of the total accumulated energy meter
sent between start and stop.
Energy for MeterValues
PARTIAL: Sends partial energy consumption while vehicle
is charging.
TOTAL: sends the actual count of the total accumulated en-
ergy meter.
Stop charge if StartTran-
saction rejects the user
YES: Stop existing charge transaction after response from
backend (StartTransaction.conf) when user is blocked, ex-
pired or Invalid.
NO: Charge transaction does not stops even if backend re-
jects the user. (StartTransaction.conf)
NOTE: Set this option according to your backend system.