Circutor URBAN - OCPP 1.5 Advanced Settings

Circutor URBAN
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
URBAN - URBAN WB
Instruction Manual
43
Value Description
Stop charge if
StartTransaction replies
ConcurrentTx
YES: Stop existing charge transaction after response from
backend (StartTransaction.conf) when user has already in-
volved in another transaction.
NO: Charge transaction does not stops even if backend re-
jects the user. (StartTransaction.conf)
NOTE: Set this option according to your backend system.
Require auth. At remote
Start
YES: Charge point sends an authorization request before
starting a new remote charge transaction request.
NO: Charge point starts a new remote charge transaction
without authorization request.
Active Power in
MeterValues
YES: Send power (Power.Active.Import) and energy (Energy.
Active.Import.Register) consumed by the vehicle within meter
values requests.
NO: Only energy consumed is sent within meter values re-
quest.
Heartbeat interval Heartbeat send interval (in seconds) for the back-end system.
Connection timeout Timeout (in seconds) before connecting to the central system.
Meter value sample
interval
Meter value sample send interval (in seconds) during charge
transaction.
NOTE: Meter values are disabled if 0 seconds is set