EasyManua.ls Logo

Circutor URBAN - OCPP 1.6 Transaction Management Settings

Circutor URBAN
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
URBAN - URBAN WB
Instruction Manual
57
Value Description
Stop transaction
when EV
unplugged
YES: Charge Transaction stops when the cable is disconnected from the
EV
NO: Charge Transaction does not stop when the cable is disconnected
from the EV; furthermore, if it is reconnected energy transfer is allowed
again. It is required for the user to present the identifier in order to stop
the Charge Transaction.
Unlock CP
side when EV
unplugged
YES: Charge Point unlocks the connector when the cable is disconnected
from the EV
NO: Charge Point keeps the connector locked when the cable is discon-
nected from the EV, it is required for the user to present the identifier in
order to unlock the connector
Supported profiles
List of supported profiles on the Charge Point
NOTE: this eld is for information purposes, it cannot be modied.
Maximum number
of configuration
Keys
Maximum number of requested configuration keys that can be requested
by the Central System.
NOTE: this eld is for information purposes, it cannot be modied.
Heartbeat interval
Number of seconds between Heartbeats.
NOTE: setting this value to 0 disables the Heartbeat.
WebSocket ping
interval
Number of seconds between Pings.
NOTE: setting this value to 0 disables the Websocket Ping/Pong.
Metervalue (select
one or more)
List of supported values used in the MeterValue.
NOTE: hold 'Ctrl' key in order to select more than one Measurand.
Transaction
message attempts
How many times the Charge Point should try to send a request to the
Central System.