URBAN - URBAN WB
Instruction Manual
57
Value Description
Stop transaction 
when EV 
unplugged
YES: Charge Transaction stops when the cable is disconnected from the 
EV
NO: Charge Transaction does not stop when the cable is disconnected 
from the EV; furthermore, if it is reconnected energy transfer is allowed 
again. It is required for the user to present the identifier in order to stop 
the Charge Transaction.
Unlock CP 
side when EV 
unplugged
YES: Charge Point unlocks the connector when the cable is disconnected 
from the EV
NO: Charge Point keeps the connector locked when the cable is discon-
nected from the EV, it is required for the user to present the identifier in 
order to unlock the connector
Supported profiles
List of supported profiles on the Charge Point
NOTE: this eld is for information purposes, it cannot be modied.
Maximum number 
of configuration 
Keys
Maximum number of requested configuration keys that can be requested 
by the Central System.
NOTE: this eld is for information purposes, it cannot be modied.
Heartbeat interval
Number of seconds between Heartbeats.
NOTE: setting this value to 0 disables the Heartbeat.
WebSocket ping 
interval
Number of seconds between Pings.
NOTE: setting this value to 0 disables the Websocket Ping/Pong.
Metervalue (select 
one or more)
List of supported values used in the MeterValue.
NOTE: hold 'Ctrl' key in order to select more than one Measurand.
Transaction 
message attempts
How many times the Charge Point should try to send a request to the 
Central System.