58
Value Description
Metervalue
sample interval
Number of seconds between MeterValue during an ongoing Charge
Transaction.
NOTE: setting this value to 0 disables the MeterValue.
Transaction
message retry
interval
Number of seconds between transaction message attempts.
NOTE: setting this value to 0 disables the attempts.
Charging cable
connection
timeout
Number of seconds the Charge Point must wait for the user to plug/
unplug the cable.
NOTE: this eld is for information purposes, it cannot be modied.
Local authList
enabled
YES: Local Authorization List enabled
NO: Local Authorization List disabled
Local auth list
max. length
Maximum size of the
Local Authorization List
, a list of identifiers that
can be synchronized with the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_localList.xml
NOTE: this eld is for information purposes, it cannot be modied.
Send local list
max. length
Maximum number of identifications that can be send in a single re-
quest from the Central System.
NOTE: this eld is for information purposes, it cannot be modied.
Reserve connector
zero supported
Yes: Charge Point supports reservations on connector 0. That res-
ervation is not done on a specific connector, one connector remains
available for the reserved idTag.
NO: Charge Point does NOT support reservations on connector 0.