7-32 P/N 13999-002 Info Manual
Section 7 Cirrus Design
Airplane Description SR20
1. Loosen retaining clamp and remove the extinguisher from its
mounting bracket.
2. Hold the extinguisher upright and pull the pin.
3. Get back from the fire and aim nozzle at base of fire at the nearest
edge.
4. Press red lever and sweep side to side.
• WARNING •
Halon gas used in the fire extinguisher can be toxic, especially
in a closed area. After discharging fire extinguisher, ventilate
cabin by opening air vents and unlatching door. Close vents
and door after fumes clear.
The extinguisher must be visually inspected before each flight to
assure that it is available, charged, and operable. The preflight
inspection consists of ensuring that the nozzle is unobstructed, the pin
has not been pulled, and the canister has not been damaged.
Additionally, the unit should weigh approximately 1.5 lb (0.7 kg). For
preflight, charge can be determined by ‘hefting’ the unit.