Cisco Firepower 4112, 4115, 4125, and 4145 Hardware Installation Guide
First Published: 2019-06-20
Last Modified: 2019-09-30
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Question and Answer IconNeed help?

Do you have a question about the Cisco 4112 and is the answer not in the manual?

Cisco 4112 Specifications

General IconGeneral
BrandCisco
Model4112
CategoryControl Unit
LanguageEnglish

Summary

Chapter 1: Overview

Features

Details the key technical specifications and capabilities of the Firepower 4100 series models.

Deployment Options

Illustrates various scenarios and use cases for deploying the Firepower 4100 in data centers.

Package Contents

Lists and illustrates the items included in the Firepower 4100 product package.

Serial Number Location

Guides users on locating the serial number and model information on the chassis.

Front Panel

Describes the components and ports located on the front panel of the Firepower 4100 chassis.

Front Panel LEDs

Explains the status indicators (LEDs) on the front panel of the Firepower 4100.

Rear Panel

Details the components and connection points found on the rear panel of the Firepower 4100.

Network Modules

Introduces optional network modules that provide various interface types for the Firepower 4100.

Hardware Bypass Network Modules

Explains the function and operation of hardware bypass network modules for fail-to-wire capabilities.

Power Supply Modules

Covers the specifications and functionality of the AC and DC power supply modules for the chassis.

Fan Modules

Describes the fan modules, their installation, and operational status indicators.

Supported SFPSFP+ and QSFP Transceivers

Lists supported transceivers for network modules and fixed ports, including safety warnings.

Hardware Specifications

Provides detailed physical and environmental specifications for the Firepower 4100 series.

Product ID Numbers

Lists Product IDs (PIDs) for the Firepower 4100 chassis and its various components.

Power Cord Specifications

Details supported power cords for different regions and their specifications.

Chapter 2: Installation Preparation

Installation Warnings

Provides essential safety warnings and instructions to be followed before installation.

Network Equipment-Building System (NEBS) Statements

Outlines NEBS compliance statements related to safety, spatial, and environmental design standards.

Chapter 3: Rack-Mount and Ground the Chassis

Unpack and Inspect the Chassis

Guides users on how to unpack the chassis and check for any shipping damage or missing items.

Rack-Mount the Chassis

Provides step-by-step instructions for mounting the Firepower 4100 chassis into a standard rack.

Ground the Chassis

Explains the mandatory procedure for grounding the Firepower 4100 chassis for safety.

Chapter 4: Installation, Maintenance, and Upgrade

Install, Remove, and Replace the Network Module

Details the process for installing, removing, and replacing network modules in the chassis.

Remove and Replace the Fan Module

Describes how to safely remove and replace the system's fan modules.

Remove and Replace the SSD

Provides instructions for removing and replacing the Solid State Drive (SSD) in the chassis.

Remove and Replace the Power Supply Module

Guides users on how to remove and replace the power supply modules for the chassis.

Connect the DC Power Supply Module

Details the process of connecting DC power input leads to the chassis power supply.

Secure the Power Cord on the AC Power Supply Module

Explains how to use tie wraps and clamps to secure power cords to AC power supply modules.

Install the FIPS Opacity Shield

Outlines the procedure for installing the FIPS opacity shield onto the chassis.