EasyManuals Logo

Cisco ASA 5545-X Cli Configuration Guide

Cisco ASA 5545-X
2164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2015 background imageLoading...
Page #2015 background image
1-13
Cisco ASA Series CLI Configuration Guide
Chapter 1 Configuring SNMP
Information About SNMP
ceSensorExtThresholdNotification
(CISCO-ENTITY-SENSOR-EXT-MIB)
Note Not supported on the
ASA Services Module.
ceSensorExtThresholdValue,
entPhySensorValue,
entPhySensorType,
entPhysicalName
The snmp-server enable traps entity
[power-supply-failure | fan-failure |
cpu-temperature] command is used to
enable transmission of the entity
threshold notifications. This notification
is sent for a power supply failure. The
objects sent identify the fan and CPU
temperature.
The snmp-server enable traps entity
fan-failure command is used to enable
transmission of the fan failure trap.
The snmp-server enable traps entity
power-supply-failure command is used
to enable transmission of the power
supply failure trap.
The snmp-server enable traps entity
chassis-fan-failure command is used to
enable transmission of the chassis fan
failure trap.
The snmp-server enable traps entity
cpu-temperature command is used to
enable transmission of the high CPU
temperature trap.
The snmp-server enable traps entity
power-supply-presence command is
used to enable transmission of the power
supply presence failure trap.
The snmp-server enable traps entity
power-supply-temperature command is
used to enable transmission of the power
supply temperature threshold trap.
The snmp-server enable traps entity
chassis-temperature command is used
to enable transmission of the chassis
ambient temperature trap.
cipSecTunnelStart
(CISCO-IPSEC-FLOW-MONITOR-MIB)
cipSecTunLifeTime,
cipSecTunLifeSize
The snmp-server enable traps ipsec
start command is used to enable
transmission of this trap.
cipSecTunnelStop
(CISCO-IPSEC-FLOW-MONITOR-MIB)
cipSecTunActiveTime The snmp-server enable traps ipsec
stop command is used to enable
transmission of this trap.
ciscoRasTooManySessions
(CISCO-REMOTE-ACCESS-MONITOR
-MIB)
crasNumSessions, crasNumUsers,
crasMaxSessionsSupportable,
crasMaxUsersSupportable,
crasThrMaxSessions
The snmp-server enable traps
remote-access
session-threshold-exceeded command is
used to enable transmission of these
traps.
Table 1-5 Supported Traps (Notifications) (continued)

Table of Contents

Other manuals for Cisco ASA 5545-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASA 5545-X and is the answer not in the manual?

Cisco ASA 5545-X Specifications

General IconGeneral
Power SupplyDual, Hot-swappable
Memory8 GB
Flash Memory8 GB
AC Input Voltage100-240 VAC
Form Factor1 RU
Number of VLANs1024
Security Contexts50
Interfaces8 x Gigabit Ethernet
Frequency50-60 Hz
Dimensions (H x W x D)1.75 x 17.5 x 12 in (4.4 x 44.5 x 30.5 cm)
High AvailabilityActive/Standby
StorageSSD (optional)