EasyManuals Logo

Cisco Firepower 2100 Series Hardware Installation Guide

Cisco Firepower 2100 Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Make sure that one power supply module is always active.
Attention
The system power requirements are lower than the power supply module capabilities. See the following table.
Note
AC Power Supply
The dual power supplies can supply up to 800-W power across the input voltage range. The load is shared
when both power supply modules are plugged in and running at the same time.
The system does not consume more than the capacity of one power supply module, so it will always operate
in full redundancy mode (2130 and 2140 only) when two power supply modules are installed.
Note
Table 5: AC Power Supply Module Hardware Specifications
2140213021202110
100 to 240 V ACInput voltage
< 6 A
< 4 AMaximum input
current
400 W250 WMaximum output
power
50 to 60 HzFrequency
89% at 50% load
85% at 50% loadEfficiency
800WMaximum
redundancy output
power
1+1 redundancy with dual power supply
modules
Redundancy
DC Power Supply
The power supplies can supply up to 350 W power across the input voltage range. The load is shared when
both power supply modules are plugged in and running at the same time.
Table 6: DC Power Supply Module Hardware Specifications
21402130
-48 to -60 V DCInput voltage
Cisco Firepower 2100 Series Hardware Installation Guide
28
Overview
Power Supply Modules

Other manuals for Cisco Firepower 2100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2100 Series and is the answer not in the manual?

Cisco Firepower 2100 Series Specifications

General IconGeneral
BrandCisco
ModelFirepower 2100 Series
CategoryFirewall
LanguageEnglish

Related product manuals