Statement 1005—Circuit Breaker
This product relies on the building’s installation for short-circuit (overcurrent) protection. To reduce risk
of electric shock or fire, ensure that the protective device is rated not greater than:
AC: 20A
DC: 40A
Warning
Statement 1017Restricted Area
This unit is intended for installation in restricted access areas. Only skilled, instructed, or qualified
personnel can access a restricted access area.
Warning
Statement 1018Supply Circuit
To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that
wiring is not overloaded.
Warning
Statement 1022Disconnect Device
To reduce risk of electric shock and fire, a readily accessible two-poled disconnect device must be
incorporated in the fixed wiring.
Warning
Statement 1025Use Copper Conductors Only
To reduce risk of fire, use copper conductors only.
Warning
Statement 1028More Than One Power Supply
This unit might have more than one power supply connection. To reduce risk of electric shock, remove
all connections to de-energize the unit.
Warning
Cisco Firepower 2100 Series Hardware Installation Guide
73
Installation, Maintenance, and Upgrade
Connect the DC Power Supply Module

Other manuals for Cisco Firepower 2100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2100 Series and is the answer not in the manual?

Cisco Firepower 2100 Series Specifications

General IconGeneral
BrandCisco
ModelFirepower 2100 Series
CategoryFirewall
LanguageEnglish

Related product manuals