Cisco ISA 3000 Industrial Security Appliance Hardware Installation Guide
Chapter 4 Technical Specifications
MIB Information
MIB Information
MIBs supported for the device can be seen by going to the SNMP configuration guide URL:
http://www.cisco.com/c/en/us/td/docs/security/asa/asa94/configuration/general/asa-general-cli/monitor
-snmp.html
From there you can find the network management MIBS URL:
http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml
Shock/Vibration
• IEC60068-2-6 and IEC60068-2-27
• MIL-STD-810, Method 514.4
• Marine EN60945
• Industrial EN61131-2/IEC61131-2
• Railway EN50155
• Smart Grid EN61850-3
• IEEE 1613
DC input voltage
• Maximum operating range: 9.6 to 60 VDC
• Rated: +/- 12 to 48 VDC
Note
• The DC-input power supply is an SELV circuit, and it can only be connected to
another SELV circuit.
Maximum DC input current
• 0.5A @ 48VDC
• 1.0A @ 24VDC
• 2.0A @ 12VDC
Power consumption 24 Watts
Description Design Specification