EasyManua.ls Logo

Cisco N9K-C93108TC-FX - User Manual

Cisco N9K-C93108TC-FX
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Cisco Nexus 93108TC-FX ACI Mode Hardware Installation Guide
First Published: 2017-04-11
Last Modified: 2019-03-28
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Cisco N9K-C93108TC-FX and is the answer not in the manual?

Cisco N9K-C93108TC-FX Specifications

General IconGeneral
ModelN9K-C93108TC-FX
SeriesNexus 9000
Product FamilyNexus
Product TypeSwitch
Switch TypeFixed
Form Factor1RU
Jumbo Frame SupportUp to 9216 bytes
CoolingFront-to-back airflow
Operating SystemCisco NX-OS
Memory16 GB
Flash Memory16 GB
MAC Address Table Size128K
Routing ProtocolBGP, OSPF, EIGRP, IS-IS
Remote Management ProtocolSNMP, CLI, NETCONF, RESTCONF
FeaturesVXLAN
Power SupplyAC or DC
Operating Temperature0 to 40 °C
Dimensions (H x W x D)1.72 x 17.3 x 21.5 in (4.37 x 43.9 x 54.6 cm)

Summary

Preface

Audience

Defines the intended audience for this publication, including hardware installers and network administrators.

Documentation Conventions

Explains the conventions used in command descriptions and their meanings.

Related Documentation

Lists other relevant Cisco documentation for ACI and Nexus switches.

Documentation Feedback

Provides instructions on how to submit feedback or report errors in the document.

Obtaining Documentation and Submitting a Service Request

Details how to access Cisco documentation and submit service requests.

Chapter 1: Overview

Overview

Provides a general introduction to the Cisco Nexus 93108TC-FX switch and its features.

Chapter 2: Preparing the Site

Temperature Requirements

Specifies the acceptable operating and non-operating temperature ranges for the switch.

Humidity Requirements

Details the humidity tolerance and recommendations for maintaining optimal conditions.

Altitude Requirements

Provides information on altitude considerations and rating based on installed power supply.

Dust and Particulate Requirements

Explains the impact of dust and particles and precautions to maintain a clean environment.

Minimizing Electromagnetic and Radio Frequency Interference

Offers guidelines to reduce EMI/RFI and prevent interference with other devices.

Shock and Vibration Requirements

States that the switch has been tested for shock and vibration standards.

Grounding Requirements

Details the importance of proper grounding for voltage stability and component protection.

Planning for Power Requirements

Outlines the switch's power supply configurations and redundancy options.

Airflow Requirements

Explains airflow directions (intake/exhaust) and how to identify them by module coloring.

Rack and Cabinet Requirements

Lists compatible rack and cabinet types for switch installation.

Clearance Requirements

Specifies the necessary clearances around the chassis for installation and airflow.

Chapter 3: Installing the Switch Chassis

Safety

Highlights important safety precautions and references the regulatory compliance document.

Installation Options with Rack-Mount Kits

Describes different rack-mount kits and positioning options for installing the switch.

Installation Guidelines

Offers general guidelines for installing the switch, including clearance, grounding, and power.

Unpacking and Inspecting the Switch

Details the process of unpacking the switch and inspecting it for damage or missing components.

Installing the Switch Using the NXK-ACC-KIT-1 RU Rack-Mount Kit

Provides step-by-step instructions for installing the switch using the NXK-ACC-KIT-1RU rack-mount kit.

Installing the Switch Using the N3 K-C3064-ACC-KIT Rack-Mount Kit

Provides step-by-step instructions for installing the switch using the N3K-C3064-ACC-KIT rack-mount kit.

Grounding the Chassis

Explains how to properly ground the switch chassis for safety and stability.

Starting the Switch

Details the process of powering on and starting the switch after installation.

Chapter 4: Connecting the Switch to the ACI Fabric

ACI Fabric Topology

Describes the key components and recommended connectivity within an ACI fabric.

Preparing to Connect to Other Devices

Lists considerations and equipment needed before connecting the switch to other devices.

Connecting Leaf Switches to APICs

Explains how to connect Cisco Nexus leaf switches to APIC controllers using various VIC modules.

Connecting Leaf Switches to Spine Switches

Details how to connect leaf switches to spine switches for optimal fabric forwarding.

Installing a Gigabit Ethernet module (GEM)

Provides steps for installing a Gigabit Ethernet module into the switch.

Virtual Port Channel Migration - Migration of Nodes from a First-Generation Switch to a Second-Generation Switch

Guides the process of migrating vPC configurations from older to newer generation switches.

Setting Up an Optional Console Interface

Describes how to configure a console interface for initial switch setup and management.

Setting Up an Optional Management Connection

Explains how to establish an out-of-band management connection for monitoring and troubleshooting.

Optic Transceiver Removal Using the Optics Extraction Tool

Details the procedure for safely removing optic transceivers using the provided extraction tool.

Maintaining Transceivers and Optical Cables

Provides guidelines for keeping transceivers and optical cables clean and in good condition.

Chapter 5: Replacing Components

Replacing a Fan Module

Explains how to replace a fan module while the switch is operating.

Installing a Fan Module

Provides steps for installing a new fan module into the switch chassis.

Replacing a Power Supply Module

Covers replacing power supply modules, emphasizing matching airflow and power types.

Replacing an AC Power Supply

Details the procedure for replacing an AC power supply module in the switch.

Replacing a High Voltage (HVAC;HVDC) Power Supply

Guides on replacing HVAC/HVDC power supply modules, noting airflow and compatibility.

Replacing a DC Power Supply

Explains how to replace a DC power supply module, including handling polarity protection.

Appendix A: Rack Specifications

Overview of Racks

Lists the types of cabinets and racks compatible with the switch installation.

General Requirements for Cabinets and Racks

Specifies general requirements for cabinets and racks, including EIA standards.

Requirements Specific to Standard Open Racks

Specifies requirements for installing the switch in open racks, including space and clearance.

Requirements Specific to Perforated Cabinets

Outlines requirements for perforated cabinets, focusing on perforation area for cooling.

Cable Management Guidelines

Provides advice on managing cables within the rack for better accessibility and airflow.

Appendix B: System Specifications

System Specifications

Overview of system specifications including environmental, dimensions, and power.

Environmental Specifications

Lists operating and non-operating environmental parameters like temperature, humidity, and altitude.

Switch Dimensions

Provides the physical dimensions (width, depth, height) of the Cisco Nexus 93108TC-FX switch.

Switch and Module Weights and Quantities

Lists the weight and quantity for the switch chassis and its various modules.

Transceiver and Cable Specifications

Directs users to resources for supported transceivers, adapters, and cables.

Switch Power Input Requirements

Details typical and maximum power consumption and heat dissipation for the switch.

Power Specifications

Provides detailed electrical specifications for different power supply modules.

500-W AC Power Supply Specifications

Lists detailed electrical characteristics for the 500-W AC power supply modules.

1200-W HVAC;HVDC Power Supply Specifications

Details electrical specifications for the 1200-W HVAC/HVDC power supply.

930-W DC Power Supply Specifications

Provides detailed electrical specifications for the 930-W DC power supply modules.

Power Cable Specifications

Specifies the power cables that can be ordered and used with the switch.

Power Cable Specifications for AC Power Supplies

Lists power cord part numbers and descriptions for AC power supplies by locale.

HVAC;HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches

Details supported HVAC/HVDC power cables with part numbers, descriptions, and photos.

DC Power Cable Specifications

Lists specifications for DC power cables, including part number and description.

Regulatory Standards Compliance Specifications

Lists regulatory standards compliance for safety and EMC.

EMC: Emissions

Specifies compliance with EMC emissions standards, such as CFR Part 15 Class A.

EMC: Immunity

Lists compliance with EMC immunity standards like EN55024 and CISPR24.

Appendix C: LEDs

LEDs

Overview of LEDs on the switch, fan modules, and power supplies.

Switch Chassis LEDs

Details the BCN, STS, and ENV LEDs on the front of the switch chassis.

Fan Module LEDs

Explains the status LEDs for the fan modules.

Power Supply LEDs

Describes the status indications for the power supply modules.

Appendix D: Additional Kits

Additional Kits

Lists optional kits available for the switch, such as rack-mount and console kits.

Rack Mount Kit NXK-ACC-KIT-1 RU

Details the contents of the 1-RU rack-mount kit NXK-ACC-KIT-1RU.

Rack Mount Kit N3 K-C3064-ACC-KIT

Details the contents of the 1-RU rack-mount kit N3K-C3064-ACC-KIT.

Appendix E: Site Preparation and Maintenance Records

Site Preparation and Maintenance Records

Overview of record-keeping for site preparation and maintenance activities.

Site Preparation Checklist

Lists planning tasks for successful switch installation, covering space, environment, and power.

Contact and Site Information

Provides a worksheet for recording contact and site-specific information for the installation.

Chassis and Module Information

Provides worksheets for recording switch chassis, network, and module information.

Related product manuals