Cisco Nexus 2000 Series Hardware Installation Guide
OL-19013-05
Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch
Cisco Nexus 2232TM-10GE, Cisco NexusN2K-C2232TM-E-10GE
For power supply specifications, see Table B-1 on page B-2. To replace a power supply, see the
“Removing and Installing Power Supplies” section on page 3-17.
For LED descriptions, see Table D-1 on page D-2.
Fan Trays
The Cisco Nexus 2232TM-10GE FEX has one fan tray that is hot swappable during operations.
Depending on whether there is a cold aisle in front of or in back of the chassis, you can order
front-to-back airflow or back-to-front airflow for the fan tray and the power supplies in the same chassis.
Table 1-15 lists the part numbers for each of the fan trays that you can use with this chassis.
To see the components used when installing a fan tray, see Figure 1-21 (front-to-back airflow) or
Figure 1-22 (back-to-front airflow).
Figure 1-21 Front-to-Back Airflow Fan Tray for the Cisco Nexus 2232TM-10GE FEX
Table 1-15 Fan Trays for the Cisco Nexus 2232TM-10GE FEX
Description Part Number
Front-to-back airflow N2K-C2232-FAN
Back-to-front airflow N2K-C2232-FAN-B
4
2
1
3
1
239292
1 Captive screws (2) 3 No black stripe indicates front-to-back airflow
2 Handle 4 Status LED